Job parameters, Active trip counter, Application rate – TeeJet IC18 SPREADER JOB COMPUTER User Manual
Page 16: Tonnage, Gate height, Density, Isobus job computer : ic18 spreader european, Main setup mode menu structure
12
www.teejet.com
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
ISOBUS Job Computer : IC18 Spreader European
JOB PARAMETERS
Job Parameters configures application settings. Options include Active Trip Counter, Application Rate, Tonnage, Gate Height and Density.
MAIN SETUP MODE MENU STRUCTURE
|
|
|
|
|
|
Counters
Job Parameters
Machine
User Interface
Communication
Help
Figure 3-13: Job Parameters
Figure 3-14: Tonnage On
1. From the Main Setup Screen , select JOB PARAMETERS.
NOTE: Settings are NOT automatically saved when selected. The
ACCEPT KEY must be selected to save the setting. Select the
ESCAPE KEY to escape without saving settings and return to
the previous menu.
Active Trip Counter
Active Trip Counter selects one of up to ten (10) active trip counters to view the
desired trip information. The trip that is “active” is displayed/active on the Operation
Screen.
• To select the Active Trip Counter, use the number pad or slide bar.
NOTE: The selected trip counter will have all data modified (added too) when
additional operations are activated. If current trip counter is not cleared,
the new data will be added to the existing data.
Application Rate
Application Rate defines a target rate of product being applied per hectare/acre.
This setting will set the same for all active trips. Range is 0 - 9999 kg/ha.
• To select the Application Rate, use the number pad or slide bar.
Tonnage
Tonnage converts pounds/kilograms to tons. It is used when the application rate
exceeds the number of digits allowed on the screen display.
• To select the tonnage mode, select an option from the drop down menu or use
the UP/DOWN ARROWS to highlight the option.
Gate Height
Gate Height is the height of the gate opening. Range is 0.0 - 99.9 cm.
• To select the gate height, use the number pad or slide bar.
Density
Density is the weight of the material being applied. Range is 0.00 - 5.00 kg/l
• To select the density, use the number pad or slide bar.