Fig. 22 — 50PEC Unit Remote-Mounted Thermostat with Deluxe D Controller Wiring

Deluxe D

Deluxe D

AL

Alarm Relay Contacts

BR

Blower Relay

CAP

Capacitor

CB

Circuit Breaker

CO

Sensor, Condensate Overflow

CR

Compressor Relay

DM

Damper Motor

FP1

Sensor, Water Coil Freeze Protection

FP2

Sensor, Air Coil Freeze Protection

FSS

Fan Speed Switch

HP

High-Pressure Switch

JW4

Jumper Wire for Alarm

LOC

Loss of Charge Pressure Switch

NLL

Night Low Limit

PB

Power Terminal Block

RVS

Reversing Valve Solenoid

TRANS

Transformer

WV

Water Valve

----------

Field Line Voltage Wiring
Field Low-Voltage Wiring

Printed Circuit Trace
Option Low Voltage Wiring

Relay/Contactor Coil

Solenoid Coil

Thermistor

Circuit Breaker

Relay Contacts-N.O.

Switch-High Pressure

Switch-Low Pressure

Ground

Wire Nut

Mate-N-Lock

>>

*Optional wiring.

NOTES:

1. Compressor and blower motor thermally protected

internally.

2. All wiring to the unit must comply with local codes.
3. Transformer is wired to 240-V (ORG) lead for 240-

1-50 units. For 220-1-50 operation, switch the RED
and ORG leads at L1 and insulate the RED lead.
Transformer is energy limiting or may have a circuit
breaker.

4. FP1 thermistor provides freeze protection for

water. When using anti-freeze solutions, cut JW3
jumper.

5. Low voltage wiring must be class 1 and voltage

rated equal or greater than unit supply voltage.

6. Factory cut jumper (JW4). Dry contact will be avail-

able between AL1 and AL2.

7. Transformer secondary ground via GRN/YEL wire

from C to control box.

8. See view A for wiring of units with water valve (part

no. 23B00112N01) or view B for units with water
valve (part no. 23B00112N03).

LEGEND