Ork problems. refer to, Table 4-1, For a – Cabletron Systems 6E133-25 User Manual
Page 43
![background image](/manuals/69013/43/background.png)
Using LANVIEW
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4-3
Table 4-1
LANVIEW LEDs
LED
Color
State
Recommended Action
CPU
Off
Power off.
Power up chassis.
Red
Blinking. Hardware
failure has occurred.
Contact the Cabletron
Systems Global Call Center
(GCC).
Solid. Resetting,
normal power up reset.
No action. If LED remains Red
for several minutes, contact
the Cabletron Systems GCC.
Amber
Blinking. Crippled.
Contact the Cabletron
Systems GCC.
Solid. Testing.
No action. If LED remains
Amber for several minutes,
contact the Cabletron Systems
GCC.
Green
Solid. Functional.
No action.
Amber
and
Green
Booting. Blinks amber
and green while
booting.
No action.
RX
Off
No link. No activity.
Port enabled or
disabled.
No error.
Green
Solid. Port enabled,
link, no activity.
No error.
Blinking. Port
disabled, link.
No error.
Amber
Flashing. Port
enabled, link, activity.
No error.
Red
Diagnostic failure.
Contact the Cabletron
Systems GCC for assistance.