Chapter 3: Installation

3-10

6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide

b.

Verify that the RJ21 connectors on the twisted pair segment have
the proper pinouts and check the cable for continuity.

c.

Check that the twisted pair connection meets the dB loss and cable
specifications outlined in

Chapter 2

.

If a link is not established, contact the Cabletron Systems Global Call
Center. Refer to

Section 1.6

,

Getting Help

, for details.

6.

Repeat steps 1 through 4, above, until all connections have been made.

3.5.3

Connecting a Twisted Pair Segment to the
FE-100TX

An FE-100-TX installed in port 25 and/or 26 has an internal crossover
switch. When connecting a workstation, use a straight-through cable and
set the Fast Ethernet Interface Module crossover switch shown in

Figure 3-6

to the crossed over position marked with X. When connecting

networking devices, such as another bridge, repeater, or router, use a
straight-through cable and set the Fast Ethernet Interface Module
crossover switch shown in

Figure 3-6

to the not crossed over position,

marked with =.

A schematic of a crossover cable is shown in

Figure 3-6

. If the wires do

not cross over, use the switch on the FE-100TX to internally cross over
the RJ45 port.

Figure 3-6

shows how to properly set the FE-100TX

crossover switch.

Figure 3-6

FE-100TX Crossover Switch

Position X
(crossed over)

1. RX+
2. RX-
3. TX+
4. NC

5. NC
6. TX-
7. NC
8. NC

Position =
(not crossed over)

1. TX+
2. TX-
3. RX+
4. NC

5. NC
6. RX-
7. NC
8. NC