5.15.11 Configuring the COM Port

The 6E12X-26 and 6E13X-25 COM ports support the following
applications:

Local Management connections

American Power Conversion Uninterruptible Power Supply (UPS)
connections

To configure the COM port, proceed as follows:

1.

Use the arrow keys to highlight the Com field.

2.

Press the SPACE bar to choose either ENABLED or DISABLED.
The COM port must be ENABLED if it will be used for Local
Management or UPS applications. Select DISABLED if you wish to
disable the COM port for additional module security.

!

CAUTION

Before altering the COM port settings, ensure that a valid IP
address is set for the module or chassis. (Refer to

Section 5.15.1

,

Setting the IP Address

.) Read this entire

COM port configuration section before changing the settings of
the COM port.

NOTE

Refer to the Release Notes included with the 6E12X-26 and
6E13X-25 to verify which COM Port applications are currently
supported.

!

CAUTION

Do NOT disable or alter the settings of the COM port while
operating the current Local Management connection through a
terminal. Altering the COM port settings disconnects the Local
Management terminal from the port, and ends the Local
Management session.

!

CAUTION

If the COM port is reconfigured without a valid IP address set
on the module or chassis, the message shown in

Figure 5-20

displays. Do not continue unless the outcome of the action is
fully understood.