beautypg.com

A.5 com port pinout assignments, A.6 regulatory compliance – Cabletron Systems 6E133-25 User Manual

Page 167

background image

COM Port Pinout Assignments

6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide

A-3

A.5

COM PORT PINOUT ASSIGNMENTS

The COM port is a serial communications port that supports Local
Management or connection to a UPS.

The COM port has the following pin assignments:

A.6

REGULATORY COMPLIANCE

Safety

The 6E12X-26 and 6E13X-25 meet the safety requirements of UL 1950,
CSA C22.2 No. 950, EN 60950, IEC 950 and 73/23/EEC.

Electromagnetic Compatibility (EMC)

The 6E12X-26 and 6E13X-25 meet the requirements of FCC Part 15,
EN 50082-1, EN 55022, VCCI V-3, CSA C108.8, AS/NZS 3548, and
89/336/EEC.

Table A-1

COM Port Pin Assignments

Pin

Signal Name

Input/Output

1

Transmit Data (XMT)

Output

2

Data Carrier Detect (DCD)

Output

3

Data Set Ready (DSR)

Input

4

Receive Data (RCV)

Input

5

Signal Ground (GND)

NA

6

Data Terminal Ready (DTR)

Output

7

Request to Send (RTS)

Input

8

Clear to Send (CTS)

NA