Haltech E6M User Manual
Page 81

75
connected on the single channel. This minimises the
amount of outputs needed to run this engine configuration.
E6M-8 and E6H-8 ONLY
Extra Injector Drivers
The “INJ 1-4 Driver” fields allow you to enable and disable injector drivers depending
on their type and the configuration you are using:
Number or Injectors
4
5
6
8
10
12
16
Low Impedance
Disable
INJ 1-4
Enable
INJ 1
Disable
INJ 2-4
Enable
INJ 1-3
Disable
INJ 4
Enable
INJ 1-4
Enable
INJ 1-4
Plus use
DB3
Driver
Box
Enable
INJ 1-4
Plus use
DB3
Driver
Box
Enable
INJ 1-4
Plus
use
DB3
Driver
Box
Injector Impedance (
Ω
)
High Impedance
Disable
INJ 1-4
Disable
INJ 1-4
Disable
INJ 1-4
Disable
INJ 1-4
Enable
INJ 1
Disable
INJ 2-4
Enable
INJ 1-2
Disable
INJ 3-4
Enable
INJ 1-4
Consult Appendix C for further information on Injectors and the E6H/E6M Injector
drivers as well as how to test for an Injector’s Impedance.
Following is a summary extracted from the wiring diagram in Appendix G which
should provide a simple guide in how to physically connect different high impedance
injector configurations: