beautypg.com

Haltech E6M User Manual

Page 81

background image


75

connected on the single channel. This minimises the
amount of outputs needed to run this engine configuration.


E6M-8 and E6H-8 ONLY

Extra Injector Drivers

The “INJ 1-4 Driver” fields allow you to enable and disable injector drivers depending
on their type and the configuration you are using:

Number or Injectors

4

5

6

8

10

12

16

Low Impedance

Disable
INJ 1-4

Enable

INJ 1

Disable
INJ 2-4

Enable

INJ 1-3
Disable

INJ 4

Enable

INJ 1-4

Enable

INJ 1-4

Plus use

DB3

Driver

Box

Enable

INJ 1-4

Plus use

DB3

Driver

Box

Enable

INJ 1-4

Plus

use

DB3

Driver

Box

Injector Impedance (

)

High Impedance

Disable
INJ 1-4

Disable
INJ 1-4

Disable
INJ 1-4

Disable
INJ 1-4

Enable

INJ 1

Disable
INJ 2-4

Enable

INJ 1-2
Disable
INJ 3-4

Enable

INJ 1-4

Consult Appendix C for further information on Injectors and the E6H/E6M Injector
drivers as well as how to test for an Injector’s Impedance.

Following is a summary extracted from the wiring diagram in Appendix G which
should provide a simple guide in how to physically connect different high impedance
injector configurations:

This manual is related to the following products: