beautypg.com

Ecu outputs, System programming requirements – Haltech E6M User Manual

Page 14

background image


8

Engine Speed Pickup

Compatible with most trigger systems:

-

5 or 12 volt square wave;

-

Pull-to-ground (open collector)

E6M and E6M-8 ONLY

An onboard reluctor adaptor is available for magnetic (or ‘reluctor’) triggers supporting most
standard tooth patterns. Applications requiring a motronic trigger input need to be specified at
the time of order. Motronic triggers with 60 teeth less 2 and 36 teeth less 1 or 2 are supported.

An external reluctor adaptor similar to that of the E6M can be used to convert a reluctor signal to a
square wave output to trigger the E6H and E6H-8.


ECU Outputs

Injector Driver

4 x 4/1Amp peak-and-hold current limiting drivers:

-

Up to four low-impedance injectors

-

Up to eight high-impedance injectors


E6M and E6M-8 ONLY

4 x extra 4/1Amp peak-and-hold current limiting drivers:

- Up to four extra low-impedance injectors
- Up to eight extra high-impedance injectors


(All units can drive an optional Driver Box. See Appendix C)

Ignition Output

To optional Haltech Ignition Module, trigger by ECU, for directly firing the coil.
(May also be compatible with other igniters. Ask your Haltech dealer.)

Special Purpose Digital Output

Up to 2 special purpose digital outputs

-

12Volt logic outputs

-

Suitable for switching fans, shift lights, anti-lag, NOS, etc.

Fuel Pump Control

20A fused relay, features automatic priming and switch-off.



System Programming Requirements

Computer

IBM-PC or compatible, preferably laptop or notebooks

CGA, EGA or VGA, colour or monochrome display

640+ kb RAM

Disk Drive

3.5" Floppy Disk Drive

(5.25" disk available on request)

Serial Port

Standard RS232C port - 9 pin D connector

(25 pin cable available on request)

COM1 or COM2 (selectable)