Ecu outputs, System programming requirements – Haltech E6M User Manual
Page 14

8
•
Engine Speed Pickup
Compatible with most trigger systems:
-
5 or 12 volt square wave;
-
Pull-to-ground (open collector)
E6M and E6M-8 ONLY
An onboard reluctor adaptor is available for magnetic (or ‘reluctor’) triggers supporting most
standard tooth patterns. Applications requiring a motronic trigger input need to be specified at
the time of order. Motronic triggers with 60 teeth less 2 and 36 teeth less 1 or 2 are supported.
An external reluctor adaptor similar to that of the E6M can be used to convert a reluctor signal to a
square wave output to trigger the E6H and E6H-8.
ECU Outputs
•
Injector Driver
4 x 4/1Amp peak-and-hold current limiting drivers:
-
Up to four low-impedance injectors
-
Up to eight high-impedance injectors
E6M and E6M-8 ONLY
4 x extra 4/1Amp peak-and-hold current limiting drivers:
- Up to four extra low-impedance injectors
- Up to eight extra high-impedance injectors
(All units can drive an optional Driver Box. See Appendix C)
•
Ignition Output
To optional Haltech Ignition Module, trigger by ECU, for directly firing the coil.
(May also be compatible with other igniters. Ask your Haltech dealer.)
•
Special Purpose Digital Output
Up to 2 special purpose digital outputs
-
12Volt logic outputs
-
Suitable for switching fans, shift lights, anti-lag, NOS, etc.
•
Fuel Pump Control
20A fused relay, features automatic priming and switch-off.
System Programming Requirements
•
Computer
IBM-PC or compatible, preferably laptop or notebooks
CGA, EGA or VGA, colour or monochrome display
640+ kb RAM
•
Disk Drive
3.5" Floppy Disk Drive
(5.25" disk available on request)
•
Serial Port
Standard RS232C port - 9 pin D connector
(25 pin cable available on request)
COM1 or COM2 (selectable)