41
4.7.4 Percentage Changes -
ƒπ
Using this function will prompt you to enter a percentage change to the selected bars. An
entry of "20" will increase each bar by 20%, while an entry of "-15" will decrease the bars by
15%. This change only affects the highlighted bar(s).
4.7.5 Linearise -
ƒλ
When a group of bars is selected (more than two), this function can be used to set the values
between the end points. Highlight the bars between two load points that are known to be
correct and press
ƒλ
. The programming software will automatically adjust all the bars
between the two end points to form a straight line. This feature facilitates fast programming
and the smoothing of maps.
4.7.6 Numeric Mode -
ƒν
This will take you into numerical mode, displaying the map as a spreadsheet. This mode is
available if required, but graphical mapping is normally used as it is easier. Numeric mode
allows you to enter the precise injection values across all the rpm and load ranges as seen in
the diagram below:
In numeric mode only a fraction of the entire map is shown on the screen but the whole
display can be accessed. To navigate the map use the cursor keys to move the highlighted
cell, to change the value of a cell, highlight that cell, type the value required and then press
the enter/return key. The values in the table must be a multiple of 0.016ms, if a different
value is entered the program will round to the nearest valid value.
To exit from Numeric Mode and go back to using the maps press the
°
key.