beautypg.com

Flintec DAD 141.1 User Manual

Page 4

background image

DAD 141.1 Technical Manual, Rev. 2.2 - February 2014

Page 4 of 54

10.7.

Auto-Transmit Commands

– SG, SN, SW, SA, SH, SM, SO, SV ...................................................... 42

10.7.1.

SG Send Gross Value continuously ............................................................................................................... 42

10.7.2.

SN Send Net Value continuously ................................................................................................................... 42

10.7.3.

SW Send Data String “Net, Gross and Status“ continuously .......................................................................... 42

10.7.4.

SA Send Triggered Average Value automatically .......................................................................................... 42

10.7.5.

SH Send Hold Value continuously.................................................................................................................. 42

10.7.6.

SM Send Peak Value continuously ................................................................................................................ 42

10.7.7.

SO Send Peak To Peak Value continuously .................................................................................................. 42

10.7.8.

SV Send Valley Value continuously ............................................................................................................... 42

10.8.

Logic Input Functions & Status

– AI’n’, IN ......................................................................................... 43

10.8.1.

AI Assign input ‘n’ [ Index 0x2074 and 0x2076 ] ......................................................................................... 43

10.8.2.

IN Read status of the logic inputs [ Index 0x210C ] .................................................................................... 43

10.9.

Logic Output Commands -

IO, OM, S’n’, H’n’, P’n’, A’n’, HT ............................................................ 44

10.9.1.

IO Read / Modify the Status of the logic Outputs [ Index 0x210A ] ............................................................. 44

10.9.2.

OM Control of the logic outputs by the host application [ Index 0x2116 ] ..................................................... 44

10.9.3.

A’n’ Assign action for setpoint ‘n’ [ Index 0x2068 ] ...................................................................................... 45

10.9.4.

S‘n’ Setpoint Value [ Index 0x206C ] .......................................................................................................... 45

10.9.5.

H’n’ Setpoint Hysteresis and Switching Action [ Index 0x206A ] .................................................................. 45

10.9.6.

P’n’ Polarity of Setpoint [ Index 0x2070 ] ..................................................................................................... 46

10.9.7.

HT Hold time for Setpoint Limit [ Index 0x2408 ] ........................................................................................ 46

10.10.

Communication Setup Commands

– AD, NA, BR, DX, OP, CL, TD .................................................. 47

10.10.1.

AD Device Address ................................................................................................................................. 47

10.10.2.

NA Network Address [ Index 0x300C ] ................................................................................................. 47

10.10.3.

BR Baud Rate ......................................................................................................................................... 47

10.10.4.

DX Operation Mode Half-/Full-Duplex ..................................................................................................... 47

10.10.5.

OP Open Device ..................................................................................................................................... 47

10.10.6.

CL Close Devices ................................................................................................................................... 47

10.10.7.

TD Transmission Delay .......................................................................................................................... 47

10.11.

Analog Output

– AA, AH, AL, AM ....................................................................................................... 48

10.11.1.

AA Analog Output Base [ Index 0x2100 ] .............................................................................................. 48

10.11.2.

AH Set Analog High Level [ Index 0x2102 ] .......................................................................................... 48

10.11.3.

AL Set Analog Low Level [ Index 0x2104 ] ........................................................................................... 48

10.11.4.

AM Set Analog Output Mode [ Index 0x2128 ] ....................................................................................... 48

10.12.

Save Calibration and Setup

– CS, WP, SS, AS, GI, PI ...................................................................... 49

10.12.1.

WP Save the Setup Parameters [ Index 0x2066 ] ................................................................................. 49

10.12.2.

SS Save Setpoint Parameters [ Index 0x2066 ] ................................................................................... 49

10.12.3.

AS Save Analogue Output Parameters [ Index 0x2066 ] ....................................................................... 49

10.12.4.

GI Get an Image File from the EEPROM ................................................................................................ 49

10.12.5.

PI Download an Image File to the EEPROM ........................................................................................... 49

10.13.

Trigger Commands

– SD, MT, GA, TE, TR, TL, SA ........................................................................... 50

10.13.1.

SD Start Delay Time [ Index 0x211A or 0x2412] ............................................................................... 50

10.13.2.

MT Measuring Time [ Index 0x210E or 0x2410 ] .............................................................................. 50

10.13.3.

GA Get Triggered Average Value [ Index 0x2008 or 0x2028 ] ............................................................. 50

10.13.4.

TE Trigger Edge [ Index 0x2402 or 0x211C ] ................................................................................... 50

10.13.5.

TR Software Trigger [ Index 0x2062 ] ............................................................................................... 50

10.13.6.

TL Trigger Level [ Index 0x211E or 0x2400 ].................................................................................... 51

10.13.7.

SA Send Triggered Average Value automatically ................................................................................... 51

11.

Use in “Approved” Applications ............................................................................................................ 52

12.

Calibration and Calibration Sequence ................................................................................................... 53

13.

Updates

– Firmware Download .............................................................................................................. 54