8. BEFORE MAKING SERVICE CALL
Symptom
Items to be checked
No picture
• Is the power supplied correctly?
• Is the lens iris adjusted correctly?
• Are the cables connected correctly?
• Is the shutter mode set correctly?
Poor color
• Is the monitor (TV) adjusted correctly?
• Is the white balance of the camera adjusted correctly?
(In modes other than automatic trace)
• Is the matrix color correction set correctly?
• Is the illumination dark?
• Is the SC phase adjusted correctly? (External sync)
Noise appears
• Is the camera connector of the camera cable loosened?
50