7. 2 Menus

• Select the menu to change the setting by referring the item “7.1 Using the Menus”.)

• When the [MENU UP], [MENU DOWN] buttons are pushed, the on the screen moves up and down.

Move the to the item to change.

(1

)

SHUTTER (Electronic shutter)

The electronic shutter has four modes; AUTO, MANUAL, SS(Synchro. Scan), EXT TRIG(External trigger).

Press the “Page” button to enter the Shutter Page. Use the “Data Up/Down” buttons to select the Shutter

Mode.

[:

AUTO-^MANUAL^

►SS ◄-►EXT TRIG

AUTO : The exposure time is controlled automatically to obtain the video level set.

MANUAL It

is possible to select the exposure time from eight speed settings;

OFF

(1/60s), 1/100s,

1/250S, 1/500S, 1/1000s, 1/2000S, 1/4000S, 1/10000s.

Note:

When setting a rapid shutter speed, sensitivity degrades according to the speed.

When a discharging light such as fluorescent lamp, etc. is used for the illumination,

the flicker may be large.

SS

: Shutter speed can be set by the horizontal scanning time (1H) unit or by the frame unit.

EXT TRIG Exposure Is performed and images are output by external trigger. EXT TRIG includes the

four modes described below. (For details of specifications, refer to the item “7.5 EXT TRIG

(External trigger)”.)

•1 PULSE SNRd Pulse Sync Non Reset)

The charge begins to accumulate after the trigger pulse is received, and 1 field images are

output according to the internal vertical sync signal timing. The exposure/accumulation time

can be set from 0.06 to 16 ms. The trigger signal timing can be set to either the rising or

falling edge.

•1 PULSE SR(1 Pulse Sync Reset)

The charge begins to accumulate after the trigger pulse is received. Upon completion of

accumulation the vertical sync signal Is reset and 1 field Images are output. The

exposure/accumulation time can be set from 0.06 to 16 ms. The trigger signal timing can

be set to either the rising or falling edge.

•2 PULSE

The charge begins to accumulate after the trigger pulse is received. Upon completion of

accumulation the vertical sync signal is reset and 1 field images are output. The

exposure/accumulation time is the time from when the first trigger signal is taken In until

the next trigger signal is taken in. The trigger signal intake timing can be set to one of

three settings: rising edge, falling edge or pulse width (front and back edges of pulse).

•RS232C

Accumulation of charges is started and ended by RS232C external control command

input, and 1 field images are output without changing the vertical sync signal timing.

19