Display

Meaning

AWB OK

Automatic white balance adjustment finished correctly.

AWB NG

LEVEL LOW

Automatic white balance adjustment cannot be performed because the video level is

too low.

Set the video level properly.

AWB NG

LEVEL HIGH

Automatic white balance adjustment cannot be performed because the video level Is

too high.

Set the video level properly.

AWB NG

C. TEMP LOW

Automatic white balance adjustment cannot be performed because the color

temperature is too low.

If the C.TEMP is set to 5600K, set to 3200K.

If the message appears with the C.TEMP set to 3200K, change the illumination or

use a color temperature conversion filter.

AWB NG

C. TEMP HIGH

Automatic white balance adjustment cannot be performed because the color

temperature is too high.

If the C.TEMP is set to 3200K, set to 5600K.

If the message appears with the C.TEMP set to 5600K, change the illumination or

use the color temperature conversion filter.

AWB NG

NOT AVAILABLE

Automatic white balance adjustment cannot be performed because the shutter speed

mode is EXT TRIG mode.

AWB NG

Automatic white balance adjustment cannot be performed for other reasons. Such as

no white area is included in an object, etc.

(D MANUAL(Manual white balance)

• Set the MODE to MANUAL on the WHT BAL menu.

(Refer to the item “7.2 (3) WHT BAL (white balance)”.)

• Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and B GAIN on the

menu, confirming with a monitor or a vector scope.

(Refer to the item “7.2 (3) (3.3) Changing each setting in MANUAL mode”.)