U lt, U------- -------------lt – Toshiba IK - TU51CU User Manual
Page 44
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
(2) 1 PULSE SR (1 Pulse Svnc Reset)
Charge begins to accumulate after the trigger input operation to the DC IN/SYNC terminal or trigger signal
input (LVDS) to the DIGITAL terminal, the vertical sync signal is reset and field images are output. The
exposure time is set to 0.06 to 16 ms on the menu.
Trigger pulse level
: (Low Level): Less than 0.5V , (High Level): 3.4V to 5V
(DC IN/SYNC terminal)
Trigger pulse fetch timing
: Rising edge / Falling edge selectable
Trigger pulse width
: More than 2us
Trigger pulse interval
: More than 33.5 ms
TRIGGER
(DC IN/SYNC terminal)
or
TRIGGER D
(DIGITAL terminal)
Internal VD
VD output
Index output
(INDEX)
Video output
_r
1
Falling edge mode
Rising edge mode
TRIGGER: Approx, ^.9цs
“TRIGGER D ; Approx. 2.4 jUS
—^ Exposure period
I
Exposure end ^ 11 to 12H
U------- -------------LT
U
~LT
un
Approx. 4.4/iS
LT
i_r
u
; Camera through picture [] : Memory picture
44