(7. 6) Changing FREEZE DISP setting
® Set the to FREEZE DISP by pushing [MENU UP], [MENU DOWN] buttons.
(D
Select either ON or OFF by pushing [DATA UP], [DATA DOWN] buttons. When ON is selected, the
word “FREEZE” appears on the frozen image.
(7. 7) Changing Negative/Positive inversion switch
0 Set the to NEGA/POSI by pushing [MENU UP], [MENU DOWN] buttons.
(D Select either NEGA (negative) or POSI (positive) by pushing [DATA UP], [DATA DOWN] buttons.
(7. 8) Changing detail signal output
0
Set the ” to DTL OUT by pushing [MENU UP], [MENU DOWN] buttons.
(D Select either ON (detail signal only is output) or OFF (video signal) by pushing [DATA UP], [DATA
DOWN] buttons.
(7. 9) Changing RS232C communication baud rate
0 Set the to BAUD RATE by pushing [MENU UP], [MENU DOWN] buttons.
(D Select either 9600bps or 19200bps by pushing [DATA UP], [DATA DOWN] buttons.
(8) Setting USER area
• When USER Is selected for the AREA of the automatic shutter or for AWB, the light measurement zones
can be changed.
• The USER area is composed of 64 zones with 8 (vertical) x 8 (horizontal) areas, and each area can be set
to ON/OFF.
0 Set the output to area menu.
Set the output to the area menu by referring to the item “7.2 (1.1) (e) Confirming the contents of the
measurement light area selected by automatic shutter” and “7.2 (3.1) (e) Confirming the contents of the
measurement light area selected by AWB”.