4-11. BATTERY SAVER
4-12. AUTOMATIC POWER OFF
The transceiver provides a battery saver mode to con
serve on battery power. The transceiver will activate the
battery saver circuit 10 seconds after the last key
operation with the squelch closed.The function will be
released by key operation or when squelch opens.
The function cannot operate during scan, or T.ALT
operations.
1. Press the F key for longer than 1 second and then press
the LOW key. S indicator will light (Initial state is ON.)
CZD
more than 1
second
C L O C K
L O W
2. The function will be released by any key operation or
when squelch opens.
3. The function can be turned off by pressing the F key
for longer than 1 second and LOW key again.
This transceiver also provides an Automatic Power OFF
circuit. The circuit action is described below. (Initial state
is ON.)
1. A 5 second audio confirmation alert will sound after
59 minutes if no signal has been received and if you
have not performed any operation.
1 minute after this alert signal the transceiver will turn
the power switch off.
2. To turn the APO function OFF/ON. press the F key for
longer than 1 second and then press the O/L.OUT key.
CO
more than 1
second
L . O U T
CO
NOTE
APO function does not activate during scan or the
TONE ALERT function in spite of lighting the APO in
dicator .