beautypg.com

Extension table, Changing needle, To remove and attach the foot holder – Kenmore 385.15208 User Manual

Page 18

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Extension Table

' Detaching the table

Pull the table away from the machine, as illustrated, for
“free-arm” sewing of cuffs and sleeves.

® Attaching the table

Push the extension table until it snaps into the machine,

0 Extension table
(2) Pin
(D Holes
d)Tab

d) Free-arm

Changing Needle

0 Needle damp screw

(D

Needle clamp

[TjTurn off the power switch.

Raise the needle to its highest position by turning the
handwheel counterclockwise, toward you, and lowering

the presser foot. Loosen the needle damp screw 0 by
turning it counterclockwise. Remove the needle from the

needle clamp

[|] Insert a new needle into the needle clamp(|)wiih the

fiat side to the rear. When inserting the needle into the
needle clamp (2), push it up as far as it goes. Tighten
the needle clamp screw 0 firmly by turning it clockwise.

[UT

o

see if the needle is good, place the flat side of the

needle onto something fiat (e.g needle plate or glass).

The gap between the needle and the flat surface should

be consistent. Never use a bent or blunt needle.
A damaged needle can cause permanent snags or runs
in knits, fine silks and silk-like fabrics.

To Remove and Attach the Foot Holder
® Thumb screw

(D

Foot holder

(D

Presser bar

»To remove

Remove the thumb screw ® by turning it counterclock­

wise with a screwdriver.

»To attach

Match the hole in the foot holder © with the threaded
hole in the presser bar (|), Fit the thumb screw © into
the hole Tighten the screw ® by turning it clockwise with
screwdriver.

10