AERCO KC Series Equipped with C-More version 3.04 User Manual
Kc series gas fired water heating system

Printed in U.S.A.
REVISED 12/10
AERCO International, Inc.
• 159 Paris Ave. • Northvale, New Jersey 07647 • Phone: 201-768-2400 • FAX: 201-768-7789
KC Series Gas Fired Water Heater
GF-111
Operation and Maintenance Manual
Applicable to Serial Numbers G-10-1232 and above
KC Series
Gas Fired
Water Heating
System
Natural Gas or Propane Fired,
Condensing and Forced Draft Hot Water Heater
1,000,000 BTU/HR Input
Patent No. 4,852,524
Table of contents
Document Outline
- KC-H-Cover-JUNE-24-2010_PN
- KC-H-TOC--1-7-10-bb
- FOREWARD A
- Section 1 – SAFETY PRECAUTIONS 1-1
- Section 2 – INSTALLATION PROCEDURES 2-1
- Section 3 – CONTROL PANEL OPERATING PROCEDURES 3-1
- Section 4 – INITIAL START-UP 4-1
- Section 5 – SAFETY DEVICE TESTING PROCEDURES 5-1
- Section 6 – MAINTENANCE 6-1
- Section 7 – TROUBLESHOOTING 7-1
- Section 8 – RS232 COMMUNICATION 8-1
- APPENDICES
- WARRANTIES W-1
- KC-H-Fwd-GF111--10-07-09-dsg-bb
- KC-H-CH1-6-22-10
- KC-H-Ch2--6-22-10
- KC-H-Ch3--7-9-10
- KC-H-Ch4-GF111--10-06-09-dsg-bb-TEST
- KC-H-Ch5--6-18-10
- SECTION 5 - SAFETY DEVICE TESTING PROCEDURES
- 5.1 TESTING OF SAFETY DEVICES
- 5.2 LOW GAS PRESSURE FAULT TEST
- 5.3 HIGH GAS PRESSURE TEST
- 5.4 LOW WATER LEVEL FAULT TEST
- 5.5 WATER TEMPERATURE FAULT TEST
- 5.6 INTERLOCK TESTS
- 5.7 FLAME FAULT TEST
- 5.8 AIR FLOW FAULT TEST
- 5.9 SSOV PROOF OF CLOSURE SWITCH
- 5.10 PURGE SWITCH OPEN DURING PURGE
- 5.11 IGNITION SWITCH OPEN DURING IGNITION
- 5.12 SAFETY PRESSURE RELIEF VALVE TEST
- SECTION 5 - SAFETY DEVICE TESTING PROCEDURES
- KC-H-Ch6-GF111_12-09-10
- 6.1 MAINTENANCE SCHEDULE
- 6.2 Spark Ignitor
- 6.3 Flame Detector
- 6.4 COMBUSTION CALIBRATION
- 6.5 SAFETY DEVICE TESTING
- 6.7 BTU TRANSMITTER ASSEMBLY
- 6.8 MANIFOLD AND EXHAUST TUBES
- 6.9 HEAT EXCHANGER INSPECTION AND CLEANING
- 6.10 CONDENSATE DRAIN ASSEMBLY
- 6.11 LOW WATER CUTOFF PROBE INSPECTION AND CLEANING
- 6.12 HYDRAULIC ZERO NEEDLE VALVE ADJUSTMENT (C-More Control BOX)
- 6.13 FLAME STRENGTH MEASURMENT
- KC-H-Ch7_09-29-10
- SECTION 7- TROUBLESHOOTING GUIDE
- 1. Inspect feed forward (BTU transmitter) sensor for loose or broken wiring.
- 2. Check resistance of sensor to determine if it is within specification.
- 1. Measure the actual exhaust temperature and continuity of the exhaust sensor. If the exhaust temperature is less than 500 o F and the exhaust sensor shows continuity replace the sensor.
- 2. If exhaust temperature is greater than 500 o F, check combustion calibration. Calibrate or repair as necessary.
- KC1000 WATER HEATER TROUBLESHOOTING TABLE – Continued
- KC1000 WATER HEATER TROUBLESHOOTING TABLE – Continued
- KC1000 WATER HEATER TROUBLESHOOTING TABLE – Continued
- KC-H-CH8-GF-111--6-17-10_FIX
- KC-H-App-A--6-18-10
- KC-H-App-B-GF109--10-01-09-dsg-bb
- KC-H-App-C 05-05-09 dsg
- KC-H-App-D--6-29-10
- KC-H-App-E--6-18-10
- KC-H-App-F-11-30-06 dsg
- KC-H-App-G--6-17-10
- KC-H-App-H-12-27-08 dsg
- KC-H-warranty dsg