Prepare required installation equipment – Kistler-Morse KM L-Cell Bolt-On User Manual
Page 11

2: Prepare for Installation
2-2
Prepare Required Installation Equipment
The following additional equipment is used to install L-Cells.
Optional Installation Kit*#39-2052-03 or -04, each complete with:
L-Cell drill template with #6-32 x 15/8” socket head cap
screw
L-Cell surfacing disk
7/64” Hex T-handle driver
Sander disks, coarse and fine (36 and 60 grit for carbon
steel, 80 and 100 grit for aluminum)
#36 cobalt HSS drill bits
#6-32, 2-flute, spiral-point taps
3/16” drill bits
Sikaflex 1A polyurethane sealant and Material Safety Data
Sheet (MSDS)
Rust-inhibiting silicone grease
(for carbon steel surface only)
KM Test Meter (optional)
Drill motor (optional)
Junction Boxes, each complete with:
•
Assy 63-1170-01 terminal board
•
Watertight fittings (4)
•
Watertight plugs
(for any cable openings that will not be used)
Microcell Order
The following items may be included with your order for each vessel
(quantities are dependent on application):
Microcells, each complete with:
•
Sensor
•
Environmental Cover
•
#8-32 socket head cap screws (2)
•
#8 hardened flat washers (2)
Junction Boxes, each complete with:
•
Assy #63-1170-01 terminal board (pipe leg application)
•
Watertight fittings (4)
•
Watertight plugs
(for any cable openings that will not be used)
Note
A signal processor and its manual are required to calibrate the
system. These may be part of your order, or you may be
planning to use an existing one.
L-Cell Installation Equipment
* Kit items are also
available individually.