Ion balance adjustment function – KEYENCE SJ-M201 User Manual

Page 9

background image

9

3-1

SJ-M Series Operations

Ion Balance Adjustment Function

The SJ-M Series automatically senses the charged level of the target body using the I.C.C. function to
automatically control the generated amount (balance) of plus and minus ions.
The zero point, the point of reference for the I.C.C. function, is adjusted before the SJ-M Series is
shipped from the factory. However, in some environments, the zero point sometimes drifts. If this
reference zero point drifts, adequate static elimination cannot be maintained. For this reason, you
must re-adjust the zero point using the "Ion Balance Adjustment Function".

The Ion Balance Adjustment Flow

The ion balance adjustment of the SJ-M Series is as follows:

Do not switch the power OFF when adjusting the Ion Balance (do not switch
off while the ion balance display lamp is blinking quickly).

CAUTION

Run Mode

Ion Balance

Adjustment Function

1 Ion Balance Adjustment Function

By holding down the

in Run Mode, you enter the Ion

Balance Adjustment Function.

Setting the Ion

Balance

2 Setting the Ion Balance

You can adjust the reference zero point of the I.C.C. function.

Saving the

adjustment values

3 Saving the Adjustment Values

By adjusting the dip switch and rotary switches, the setting
values are saved to the main device.

Run Mode

3-1

SJ-M Series Operations

1. Ion Balance Adjustment Function

The Ion Balance Adjustment Function allows you to adjust the reference zero point of the I.C.C.
function.
By holding down the

for more than one second in Run Mode, you enter the Ion Balance

Adjustment Function. To return to Run Mode, press the

while in the Ion Balance Adjustment

Function for a short time.

2. Ion Balance Setting

Adjust the ion balance using

while in the Ion Balance Adjustment Function. The LED on the

ion monitor corresponding to the set value lights up.

Pressing

fixes the ion balance. By pressing

, the ion monitor displays the progress bar (all

blinking green).

The unit starts up in the Run Mode after the power is turned ON, or after static
elimination is stopped.
Ion Balance Adjustment cannot be conducted within one minute of the power
being turned ON or after static elimination is stopped.

Either lights up “BALANCE” blinks

[Run Mode]

[Ion Balance Adjustment Function]

Press
for a
short time.

Hold down
for at least
1 second

Reference

Key

Function

Key

Shifts the zero point in the + direction.

Key

Shifts the zero point in the – direction.

The progress bar display blinks for approximately one minute.

Blink at high speed

Progress Bar
Display

Reference

3-1

SJ-M Series Operations

3. Saving adjustment values

Once the progress bar is complete, the LED for the ALARM/ION LEVEL/COND blinks red or lights up
red. Remove the rubber covering to the lower right controller, then using the dip and rotary switches,
save the ion balance setting values to the main device. Once all the ALARM/ION LEVEL/COND LEDs
light up red, the ion balance adjustment is complete. After setting is complete, replace the rubber
covering back onto the controller.

(1) ALARM LED

Adjust the dip switch positively or negatively in order to change the ALARM LED from blinking red to
solid red.

(2) ION LEVEL LED

Adjust the left rotary switch, changing the ION LEVEL LED from blinking red to solid red.

Dip switch

Rotary switch

3-1

SJ-M Series Operations

(3) COND LED

Adjust the right rotary switch, changing the COND LED from blinking red to solid red.

(4) Check that all ALARM/ION LEVEL/COND LEDs are lit up red, then push

for a short time.

Once the display changes to Run Mode, setting is complete.

Setting the dip switch position to 0 will deactivate the Ion Balance Adjustment
Function.

Rotary switch

Push for a short time

Reference