2 specifications, 3 external dimensions, Specifications – KEYENCE SJ-M201 User Manual
Page 13: External dimensions
13
5-2
Specifications
This section provides the specifications of the SJ-M201 Series.
■ Static Elimination Head/Controller Unit
*1: Values obtained at an installation distance of 50 mm and air flow rate of 60 Nl/min (ambient operating
temperature +20 to +30°C, ambient operating humidity 40 to 60% RH) (without nozzle)
*2: Values obtained at an installation distance of 50 mm and air flow rate of 20 Nl/min (ambient operating
temperature +20 to +30°C, ambient operating humidity 40 to 60% RH) (without nozzle)
*3: Inquire for derating of humidity/pressure in environments exceed +35°C.
Use clean, dry air at a temperature of -20°C or less. Air pressure varies
by the model of nozzle used (see the chart to the right).
*4: During regular use, supply air at a supply temperature of +40°C or less.
*5: These values are for the High-pressure Cable Unit only. The ambient
operating temperature is 0 to +40°C for other parts.
*6: When the ambient temperature exceeds +40°C, perform derating
according to the following figures.
●
Temperature/humidity derating graph
Model
Static Elimination Head
SJ-M021/SJ-M021G
Controller Unit
SJ-M201
Voltage application method
Pulse AC
Applied voltage
±5.5 kV
Rated output voltage
±6 kV
Ion balance control method
I.C.C. method
Static elimination time
0.5 sec. max.
*1
Ion balance
±15 V or less
*2
Max. air pressure
0.001 to 0.5 MPa
*3
Control input
Static elimination stop input
No-voltage input
Control output
Alarm output
NPN open collector
100 mA 40 V or less
Ion level alarm output
Condition alarm output
Rating
Power voltage
24 VDC ±10%
Current consumption
450 mA max.
Environmental
resistance
Operating
ambient
temperature
Head
0 to +80°C
*4, 5, 6
Controller
0 to +40°C
Operating ambient humidity
35 to 65%RH
Weight
Static Elimination Head
Approx. 600 g
Controller Unit
Approx. 300 g
Nozzle
Min. air pressure
without nozzle
0.001MPa (2.6Nl/min)
SJ-ML
0.02MPa (20Nl/min)
SJ-MS/ML1
0.03MPa (20Nl/min)
SJ-MS/ML2
0.02MPa (20Nl/min)
SJ-MS/ML3
0.08MPa (50Nl/min)
SJ-MS/ML4
0.08MPa (50Nl/min)
0.6
0.5
0.4
0.3
0.2
0.1
0
0
10
20 30
40 50
60
70
80
70
60
50
40
30
20
10
40
50
60
70
80
0
A
mbient
oper
at
ing humid
ity (% RH)
Ambient operating temperature (°C)
Max. op
er
at
ing
pr
essu
re (MP
a)
Ambient operating temperature (°C)
5-2
Spe
c
ifi
c
ations
■ AC Adapter
*The AC cable is for domestic use only (voltage rating 125 V).
Model
SJ-U2
Rating
Rated input
100 to 240 VAC (50/60 Hz)
Rated output
24 VDC 2.65 A
Environmental resistance
Operating ambient temperature
0 to +35°C
Operating ambient humidity
20 to 80% (condensation not allowed)
Weight
Approx. 250 g
5-3
External Dimensions
This section presents the external dimensions of the SJ-M Series.
n Body
Static Elimination Head
Controller Unit SJ-M201
6 mm dia. cable length 300 mm
(min. bend radius 15)
2-
φ
4.4(thru hole)
24
3
φ
15
51
191
181
9 mm dia. cable length 2 m
(min. bend radius 50)
24
60
35
(allowable mounting
fixture range)
58
φ
10
φ
12
11.5
5
131
5
8.5
34
2.5
Rc 1/8
(male tapered
screw)
22
34.5
SJ-M021 (G)
5
70
120
32
36
46
76
50
5-3
External Dimensions
■ Mountin
g
fixture
■ Dis
c
har
g
e prevention
c
ap
■ Extension
c
able (SJ-C3)
■ AC adapter (SJ-U2)
* For details of the AC cable, contact your local KEYENCE sales office.
28.2
20
10
2-long hole *
(Installation hole)
Mounting fixture (top)
10.5
t=0.8
10.2
3.4
2.6
* Long hole dimensions
Mounting fixture (bottom)
2-
φ3.4
30
20
10
3
60.5
11.5
25
17
M3 set screw
OP-75354
Mountin
g
fixture
6 mm dia.
cable length 3 m
49
φ15.5
51
φ15
(37.5)
7
ш16
(10.3)
(1
6.3)
50.5
(12.5)
(1
4)
28
ш3.5
1800