5-2

Specifications

This section provides the specifications of the SJ-M201 Series.

Static Elimination Head/Controller Unit

*1: Values obtained at an installation distance of 50 mm and air flow rate of 60 Nl/min (ambient operating

temperature +20 to +30°C, ambient operating humidity 40 to 60% RH) (without nozzle)

*2: Values obtained at an installation distance of 50 mm and air flow rate of 20 Nl/min (ambient operating

temperature +20 to +30°C, ambient operating humidity 40 to 60% RH) (without nozzle)

*3: Inquire for derating of humidity/pressure in environments exceed +35°C.

Use clean, dry air at a temperature of -20°C or less. Air pressure varies
by the model of nozzle used (see the chart to the right).

*4: During regular use, supply air at a supply temperature of +40°C or less.
*5: These values are for the High-pressure Cable Unit only. The ambient

operating temperature is 0 to +40°C for other parts.

*6: When the ambient temperature exceeds +40°C, perform derating

according to the following figures.

Temperature/humidity derating graph

Model

Static Elimination Head

SJ-M021/SJ-M021G

Controller Unit

SJ-M201

Voltage application method

Pulse AC

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec. max.

*1

Ion balance

±15 V or less

*2

Max. air pressure

0.001 to 0.5 MPa

*3

Control input

Static elimination stop input

No-voltage input

Control output

Alarm output

NPN open collector

100 mA 40 V or less

Ion level alarm output
Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental
resistance

Operating
ambient
temperature

Head

0 to +80°C

*4, 5, 6

Controller

0 to +40°C

Operating ambient humidity

35 to 65%RH

Weight

Static Elimination Head

Approx. 600 g

Controller Unit

Approx. 300 g

Nozzle

Min. air pressure

without nozzle

0.001MPa (2.6Nl/min)

SJ-ML

0.02MPa (20Nl/min)

SJ-MS/ML1

0.03MPa (20Nl/min)

SJ-MS/ML2

0.02MPa (20Nl/min)

SJ-MS/ML3

0.08MPa (50Nl/min)

SJ-MS/ML4

0.08MPa (50Nl/min)

0.6

0.5

0.4

0.3

0.2

0.1

0

0

10

20 30

40 50

60

70

80

70

60

50

40

30

20

10

40

50

60

70

80

0

A

mbient

oper

at

ing humid

ity (% RH)

Ambient operating temperature (°C)

Max. op

er

at

ing

pr

essu

re (MP

a)

Ambient operating temperature (°C)

5-2

Spe

c

ifi

c

ations

AC Adapter

*The AC cable is for domestic use only (voltage rating 125 V).

Model

SJ-U2

Rating

Rated input

100 to 240 VAC (50/60 Hz)

Rated output

24 VDC 2.65 A

Environmental resistance

Operating ambient temperature

0 to +35°C

Operating ambient humidity

20 to 80% (condensation not allowed)

Weight

Approx. 250 g

5-3

External Dimensions

This section presents the external dimensions of the SJ-M Series.

n Body

Static Elimination Head

Controller Unit SJ-M201

6 mm dia. cable length 300 mm
(min. bend radius 15)

2-

φ

4.4(thru hole)

24

3

φ

15

51

191

181

9 mm dia. cable length 2 m
(min. bend radius 50)

24

60

35

(allowable mounting
fixture range)

58

φ

10

φ

12

11.5

5

131

5

8.5

34

2.5

Rc 1/8
(male tapered
screw)

22

34.5

SJ-M021 (G)

5

70

120

32

36

46

76

50

5-3

External Dimensions

Mountin

g

fixture

Dis

c

har

g

e prevention

c

ap

Extension

c

able (SJ-C3)

AC adapter (SJ-U2)

* For details of the AC cable, contact your local KEYENCE sales office.

28.2

20

10

2-long hole *
(Installation hole)

Mounting fixture (top)

10.5

t=0.8

10.2

3.4

2.6

* Long hole dimensions

Mounting fixture (bottom)

2-

φ3.4

30
20

10

3

60.5

11.5

25

17

M3 set screw

OP-75354

Mountin

g

fixture

6 mm dia.
cable length 3 m

49

φ15.5

51

φ15

(37.5)

7

ш16

(10.3)

(1

6.3)

50.5

(12.5)

(1

4)

28

ш3.5

1800