Initial reset (Reset to the default state)

This function cancels all the functions you set and allows the
equipment to be reset to the default state.

• The initial reset can be set on the main display only.
• The initial reset cannot cancel "span adjustment results".

1

When in the main display, while
pressing the [MODE] button, press
the [SET] button five times.

"rSt.no" will appear.

2

Press the top/bottom Arrow buttons
to select "rSt.YES".

3

Press the [MODE] button.

"rSt.End" will appear.
The initial reset is completed.

Switching the display unit

The display unit can be switched from the initial reset screen.
This section explains how to switch from "mm" display to "inch" display.

1

Display "rSt.YES" from the initial reset screen.

Refer to "Initial reset" for more details on how to display "rSt.YES".

2

Pressing the [MODE] button, press the [SET] button for 2
seconds or more.

3

Use the up and down Arrow button to
select "inch".

4

Press the [MODE] button.

"rSt.End" will appear.
Switching the display unit is completed.

Setting Mode Display

Function setting mode

You can set the following functions in the function setting mode.

No.

Item

Description

Detection mode Select the detection mode.

Response
time

Longer response time makes the average
data time longer, which stabilizes the value.

Timing type

For the timing input, select "External timing"
or "Self timing (internal timing)".

Self timing
level

When the self timing is selected in

, set

the self timing level.

Self timing
delay type

When the value rises above (or falls below) the
self timing level with "Std" selected in

,

select "Fix the criterion value when the setting
time is elapsed" or "Fix the criterion value after
the display value is stabilized (static hold)".

User specified
delay time

Set the delay time when "Fix the criterion value
when the setting time is elapsed" is selected in

.

Static hold
delay stability
criterion

Set the reference of stability criterion when "Fix
the criterion value after the display value is
stabilized (static hold)" is selected in

.

Static hold
delay stability
width

Enter the optional numerals when USEr (user
specification) is selected in

.

Calculation
mode

Set the calculation method when an
expansion unit(s) is added. *The calculation
mode will appear only when an expansion
unit(s) is added.

Note

MODE

Standard

Detection mode (press and hold the [MODE] button in the main screen)

NG hold

Peak hold

Bottom hold

Peak to peak

Display for entering the setting value

Response time

MODE

External timing input

Timing type

Rising self

Falling self

MODE

Available to set only when any of Std, P-H and b-H is selected in [ Detection mode].

MODE

Display for entering the setting value

Self timing level

Available to set only when item other than t-in is selected in [ Timing type].

MODE

Static hold

Self timing delay type

Available to set when the following conditions are provided.

Std is selected in [ Detection mode].

Item other than t-in is selected in [ Timing type].

Delay timer

MODE

Display for entering the setting value

User specified delay time

Available to set only when t.d is selected in [ Self timing delay type].

MODE

Default

Static hold delay stability criterion

Available to set only when Stb.d is selected in [ Self timing delay type].

User

Display for entering the setting value

Static hold delay stability width

Available to set only when USEr is selected in [ Static hold delay stability criterion].

MODE