The initial reset initializes all settings except for the calibration setting.

The initial reset can also be used to change the judgment output and analog output

settings.

1

While holding down the [MODE] button on the main screen,

press the [SET] button 5 times.

[TGUGV] will be displayed on the main display.

2

Press S/T button to select [[GU] and press the

[MODE] button.

If [PQ] is selected, the settings of output polarity and

analog output can be changed without initial reset.

3

Press S/T button to select the output polarity

and press the [MODE] button.

4

Press the S/T button to select the analog

output and press [MODE] button.

After the initialization is complete, [GPF] blinks several times on the sub display

and the main screen is restored.

z

Calling the setting display

Hold the [MODE] button for approx. 2 seconds on the main screen.
The setting display appears.

„

Basic operations on the setting display

To change the setting, press the S/T button

To move the next item, press the [MODE] button or X button

To return to the previous item, press the W button

To skip the rest of the settings and finish, press and hold the [MODE] button for

approx. 2 seconds

Setting procedures (Basic)

Basic setting

„

1. Measurement mode [(0E]

Select whether to display the received light (or blocked light) of the laser beam

emitted to the receiver as a dimension (mm) or a percentage (%) in respect to the

measurement range.

„

2. Received/Blocked light mode [.F]

Select whether to display according to the light transmitted into the receiver or

according to the amount of light blocked.

„

3. Averaging/High-pass filter [#X']

z

Averaging

The average value is moved and averaged. If the measured values fluctuate, stable

measurements can be obtained by increasing the average number of times. When

[*2(] is set, the high-pass filter will be enabled.

z

High-pass filter

This function ignores fluctuations which are less than an arbitrary frequency (cut-off

frequency), and displays the results. This is effective to ignore gradual changes

and only capture the sudden changes. When [*2(] is selected on the averaging

setting screen, the cut-off frequency setting screen will open.

„

4. Output mode [QWV]

Setting the judgment output method

Initial Reset (Initialize)

Setting value

Description

PRP

NPN output

RPR

PNP output

Setting value

Description

QHH

Not using the analog output

W

Analog output range is from 0 to 5 V.

W

Analog output range is ±5 V.

W

Analog output range is from 1 to 5 V.

C/RT

Analog output range is from 4 to 20 mA.

If any button other than the S/T button and [MODE] button are

pressed halfway through the initial reset procedure, the initial

reset is stopped and returned to the screen displayed in step 2.

Setting Method

Main screen

Press the [MODE] button for 2 seconds.

"1. Measurement
mode"

Use S/T to select.

The % mode and dimension mode are set.

Press the [MODE] or X button.

"2. Received/
Blocked light
mode"

Use S/T to select.

The received light mode and blocked light

mode are set.

Press the [MODE] or X button.

"3. Averaging/
High-pass filter"

Use S/T to select.

Set the number of averages. When HPF is

selected, set the high-pass filter.

Press the [MODE] or X button.

"4. Output mode"

Use S/T to select.

Set N.O. (Normally Open) or “N.C.

(Normally Closed).

Press the [MODE] or X button.

"Basic setting
complete"

Press the [MODE] button or X button to

return to the main screen.

Press the T or S button.

"Advanced settings"

IB Series User's Manual

Press the W button to return to the main screen.

When Advanced Settings is selected, the

following items can be set. Refer to the IB Series

User’s Manual for details.

“5. Hold function”, “6. Timing input”, “7. Delay

timer”, “8. Hysteresis”, “9. Analog output

scaling”, “10. External input”, “11. Bank

switching method”, “12. Save zero-shift state”,

“13. Save adjust state”, “14. Adjust level”, “15.

Auto adjust function", “16. Check output

function”, “17. Error output mode”, “18. Display

digit”, “19. Power save function”, “20. Judgment

indicator color”, “21. P.V. value display color”

Press the [MODE] or X button.

Advanced setting

;GU

T'5'V

Performing the initial reset

PRP

QWV

Output polarity

QHH

#P.)

Analog output

Reference

2EV

(PE

.K)JV

.F

#W'

PQ

QWV

'PF

2TQ

Setting value

Description

Default value

2EV

Display as a percentage (%) in respect to the
measurement range.

c

.'P

Display as a dimension (mm).

Setting value

Description

Default value

.K)J6

Display according to the amount of laser beam
transmitted into the receiver.

c

&#T-

Display according to the blocked light (amount of
shadow).

Each sensor head’s measurement status and R.V. (internal

measurement value) when set to the "1. Measurement mode" and "2.

Received/Blocked light mode" are as follow.

Received/Blocked

light mode

.

.K)J6

F#T-

Measurement mode

2EV

.'P

2EV

.'P

Totally unblocked

IB-01

100.00 1.000 0.00 0.000

IB-05

100.00 5.000 0.00 0.000

IB-10

100.00 10.000 0.00 0.000

IB-30

100.00 30.00 0.00 0.00

Partially blocked

IB-01

50.00 0.500 50.00 0.500

IB-05

50.00 2.500 50.00 2.500

IB-10

50.00 5.000 50.00 5.000

IB-30

50.00 15.00 50.00 15.00

Totally blocked

IB-01

0.00 0.000 100.00 1.000

IB-05

0.00 0.000 100.00 5.000

IB-10

0.00 0.000 100.00

10.000

IB-30

0.00 0.00 100.00

30.00

Item

Setting range

Default value

Averaging

//////////*2(

Item

Setting range

Default value

Cut-off frequency

/////////

The following process takes place when the high-pass filter is set.

Setting value

Description

Default value

PQ

Output is normally open.

c

PE

Output is normally closed.

Reference

Reference

Measured

value

Input waveform

Waveform onto

which high-pass

filter was applied

Time

Time

Measured

value

Reference

Normally open [PQ]

Judgment

Judgment output

HIGH

GO

LOW

HIGH

ON

OFF

OFF

GO

OFF

ON

OFF

LOW

OFF

OFF

ON

Error

ON

OFF

ON

[]

OFF

OFF

OFF

Normally closed [PE]

Judgment

Judgment output

HIGH

GO

LOW

HIGH

OFF

ON

ON

GO

ON

OFF

ON

LOW

ON

ON

OFF

Error

OFF

ON

OFF

[]

ON

ON

ON