*3 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion
units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion
units are connected), power voltage or less, residual voltage 2 V or less
*4 Use with the over current protection device which is rated 30 V or more and not
more than 1 A.
*5 Does not include the power consumption of the load. The power consumption
with expansion units installed is the total of each amplifier unit’s power
consumption.
Example: When using one main unit (IB-1000) with two expansion units
(IB-1050)
(2400 mW X 1) + (2400 mW X 2) = 7200 mW
Sensor head
*1 Classified based on IEC60825-1 following the requirements of FDA (CDRH)
Laser Notice No. 50.
*2 Value when measuring the target (white diffuse object) at the middle of the
transmitter and receiver position, and at the center of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm, and light is
half-blocked at a position 150 mm from receiver.
Deflection width (±2
) when sampled for 30 seconds with an average number
of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm and full light
is received.
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and
not to represent that the Products would necessarily conform to said
models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE
for inspection and examination. Upon examination by KEYENCE,
KEYENCE, at its sole option, will refund the purchase price of, or repair or
replace at no charge any Products found to be defective. This warranty
does not apply to any defects resulting from any action of Buyer, including
but not limited to improper installation, improper interfacing, improper
repair, unauthorized modification, misapplication and mishandling, such as
exposure to excessive current, heat, coldness, moisture, vibration or
outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various
Products. They are only suggestions, and it is Buyer's responsibility to
ascertain the fitness of the Products for Buyer’s intended use. KEYENCE
will not be responsible for any damages that may result from the use of the
Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are
not to be used internally in humans, for human transportation, as safety
devices or fail-safe systems, unless their written specifications state
otherwise. Should any Products/Samples be used in such a manner or
misused in any way, KEYENCE assumes no responsibility, and additionally
Buyer will indemnify KEYENCE and hold KEYENCE harmless from any
liability or damage whatsoever arising out of any misuse of the Products/
Samples.
(4)
OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT
OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING
FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF
INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR
ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE
OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE
OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD
PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
BUYER. In some jurisdictions, some of the foregoing warranty disclaimers
or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered
to a third party, Buyer must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Products/Samples.
E 1110-2
Model
IB-01
IB-05
IB-10
IB-30
Light source
Visible semiconductor laser Wavelength: 660 nm
Laser
Class
Class 1 (IEC60825-1, FDA (CDRH) Part 1040.10
*1
)
Installation
distance
0 to 2000 mm
0 to 300 mm
Measurement
range
1 mm
(Installation distance
0 to 300 mm)
1 to 2.5 mm
(Installation distance
300 to 2000 mm)
5 mm
10 mm
30 mm
Sampling rate
12,500 times/sec. (80
s)
Minimum
detection target
*2
8 m
(Installation distance 0
to 300 mm)
8 to 50 m
(Installation distance
300 to 2000 mm)
0.05 mm
0.1 mm
0.2 mm
Repeatability
*3
5
m (distance 0 to
300 mm)
5
m
5
m
10
m
Temperature
characteristics
*4
±0.2 % of F.S./°C
±0.1 % of F.S./°C
(±5
m)
±0.1 % of F.S./°C
(±10
m)
±0.1 % of F.S./°C
(±30
m)
Operating
indicators
Laser emission warning indicator: green LED
E
nvironme
nta
l r
esistan
ce
Operating
ambient
luminance
Incandescent lamp:
5000lx
Solar light: 10000lx
Incandescent
lamp: 5000lx
Solar light:
5000lx
Incandescent lamp: 10000lx
Solar light: 10000lx
Operating
ambient
temperature
0 to +40 °C
(no freezing)
0 to +50 °C (no freezing)
Relative
humidity
35 to 85 % RH (no condensation)
Vibration
Amplitude 1.5 mm 2 hr each for X, Y and Z axes
Ma
ter
ia
l
Housing
PBT
Galvanized die cast
Lens cover
Glass
Cable
PVC (2 m)
Weight
Approx. 140 g
Approx. 180 g Approx. 220 g Approx. 510 g