beautypg.com

KEYENCE IB Series User Manual

Ib series, Laser thrubeam sensor, Instruction manual

background image

1

Laser Thrubeam Sensor

IB Series

Instruction Manual

Read this manual before using the product in order to achieve maximum performance.

Keep this manual in a safe place after reading it so that it can be used at any time.

For details of functions, refer to the IB Series User's Manual.

Symbols

The following symbols are used in this manual to alert you to important matters for

preventing personal injury and device damage.

Reference pages are indicated.

General precautions

* The classification is implemented based on IEC60825-1 following the requirement

of Laser Notice No.50 of FDA (CDRH).

• Refer to the “Thrubeam Type Laser Detection Sensor IB Series User’s

Manual” for details on each function.

• The “Laser Thrubeam Sensor IB Series User’s Manual” can be downloaded

from the KEYENCE web site (http://www.keyence.com).

It indicates a hazardous situation which, if not avoided, will result

in death or serious injury.
It indicates a hazardous situation which, if not avoided, could

result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could

result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in

product damage as well as property damage.

It indicates cautions and limitations that must be followed during operation.

It indicates additional information on proper operation.

It indicates tips for better understanding or useful information.

Safety Information for IB Series

• This product is just intended to detect the object(s). Do not

use this product for the purpose to protect a human body or a

part of a human body.

• This product is not intended for use as explosion-proof

product. Do not use this product in a hazardous location and/

or potentially explosive atmosphere.

• Provide sufficient safety measures to prevent various damage

in the event this product fails.

• When using this product in combination with other devices,

there may be cases when the functions and performance

cannot be achieved because of the working conditions or

environment, etc. Always review the combination carefully

before starting use.

• Do not apply sudden temperature changes on any device

including the peripheral devices. Condensation could cause

device damage.

Safety Precautions on Laser Products

• This product uses a semiconductor laser for the light source.

• Use of controls or adjustments or performance of procedures

other than those specified herein may result in hazardous

radiation exposure.

• Follow the instructions mentioned in this manual. Otherwise,

injury to the human body (eyes and skin) may result.

Precautions on Class 1 laser products

• Do not stare into the beam.

• Do not disassemble this product. Laser emission from this

product is not automatically stopped when it is disassembled.

Model

IB-01/IB-05/IB-10/IB-30

Wavelength

660 nm

Output

170 μW

Pulse width

30 μs

FDA (CDRH) Part1040.10

*

Class 1 Laser Product

IEC 60825-1

Class 1 Laser Product

DANGER

WARNING

CAUTION

NOTICE

Important

Point

Reference

WARNING

NOTICE

WARNING

Laser emission stop input

When laser emission stop input is set as an external input, laser

emission can be stopped by turning on the external input (2 ms

or more). Laser emission stays stopped while the external input

is on. The laser is emitted within 3 ms after the external input is

turned off. For the conditions of detection outputs and analog

outputs during laser emission stop input, refer to the User's

Manual.

Troubleshooting

Turn the power OFF immediately in the following cases.

Continuing use in an abnormal state can cause damage.

• When water or foreign matter enters the product body.

• When the product has been dropped or the case damaged.

• When smoke or abnormal odors are emitted from the product.

Precautions for Use

• Use this product with the correct power voltage. Failure to do

so could result in fire or electric shock.

• Do not disassembly or modify this product. Failure to observe

this could result in fire or electric shock.

• Always turn off the power of the main unit and any device

connected to the main unit before connecting or

disconnecting a cable.

• Do not turn the power off while setting the items. Doing so

could result in the lost of some or all setting data.

Installation Environment

To ensure correct and safe use of this product, do not install it in

the following type of environment. Failure to observe this could

result in faults.

• Location subject to high levels of moisture or dust, or which is

poorly ventilated

• Location subject to high temperatures, such as where product

is subject to direct sunlight

• Location subject to corrosive gases or flammable gases

• Location directly subject to vibration or impact

• Location which may be subject to water, oil or chemical spray

• Location where static electric is easily generated

Effect of Contaminants

• Contaminants such as dirt, dust, water or oil may prevent a

correct measurement from being made.

• Spray any contaminants off the transmitter and receiver

sections with clean air. If heavily contaminated, wipe the

sections off with a soft cloth dampened with alcohol.

• Spray any contaminants off the measurement target with

clean air, or wipe them off.

• If contaminants are suspended in the measurement range,

install a protective cover, or perform air purging, etc.

Measures for Noise

When installing this product near a source of noise such as a

power cable or high voltage cable, it could malfunction or fail

because of the noise. Provide counter measures for noise such

as installing a noise filter, laying the cables in a separate conduit,

or insulating the amplifier unit or sensor head.

Warming Up

Wait at least 30 minutes after turning the power on before

starting use. The circuit will be unstable immediately after the

power is turned on so the display value may gradually fluctuate.

Power On Reset

Once the power is turned on, it will take approx. 2 seconds for the

measurement to start. The judgment output will be output after

the response time (average number of times X sampling rate) has

elapsed.

Other Precautions

Power Supply

• The product could malfunction by the noise superimposed on

the power supply. Use a DC stabilized power supply with

insulated transformer for the power supply.

• When using a commercially-available switching regulator,

always ground the frame ground terminal.

Point

WARNING

WARNING

CAUTION

NOTICE

WARNING

96M11417

Table of contents