Amplifier wiring, Amplifier functions and displays, Setting method – KEYENCE IB Series User Manual
Page 5: Main screen, Attaching the sensor head cable connector
5
3
Attach the transmitter’s sensor head connection cable to the
amplifier’s [T] connector.
The connection procedures are the same as the receiver side.
Attaching the sensor head cable connector
(OP-87060: optional)
Cut the sensor head cable to the required length and attach the new connector to
use the sensor. The connection method is the same for the transmitter and receiver.
1
Cut the cable to the required length and strip approx. 15 mm of
insulation from the end.
2
Insert each color coded cable into the same colored marked
points on the connector.
Each cable is secured temporarily when it is inserted completely.
3
Confirm that all the cables are inserted properly into the
connector and crimp them using pliers or a similar tool.
Amplifier wiring
z
Connecting power/Input-output cable (IB-1500/IB-1550 panel
mount type)
Connect the power/Input-output cable to the panel mount type main unit and
Input-output cable to the expansion units.
z
Power/Input-output cable
The following information shows the details of power/Input-output cable. For
information about the input-output circuit, see page 10 of this Instruction Manual.
*1 IB-1050/IB-1550 (expansion unit) do not have brown, blue, or light blue wires.
Power is supplied to the expansion units through the IB-1000/IB-1500 (main unit).
*2 The Analog output can be set for the following: Not used (OFF), 0 to 5 V, r5 V, 1
to 5 V and 4 to 20 mA.
"Operation When the Power Is Turned On for the First Time" (Page 6)
"Initial Reset (Initialize)" (Page 8).
*3 In addition to the selections noted on the image above, the external inputs can
also be selected to perform the following: Bank A input, Bank B input, Laser
emission stop input and Not used (OFF).
Setting method
Main screen
Main screen
z
P.V. (judgment value) and R.V. (internal measurement value)
R.V. value (internal measurement value) is the measurement value displayed on the
sensor amplifier.
* R.V. = Raw Value
P.V. (judgment value) is the value used for setting the judgment output to ON or OFF
based on the tolerance setting value. Also, the analog output is based on the P.V.
value.
* P.V. = Present Value
"Setting the Tolerance Setting Value" (Page 7)
The P.V. (judgment value) and R.V. (internal measurement value) are basically the
same, however, those values differ when the hold function is used.
z
Main display (Upper level)
P.V. (judgment value) is displayed on the main display. Normally, the display differs
as shown below when using the hold function.
Do not strip the core wire insulation.
Once the connector has been installed, make sure to connect
it to the amplifier and confirm that the sensor operates
normally.
If the sensor head does not function properly, crimp the
connector again using pliers or a similar tool.
Once the connector is crimped, it cannot be reused.
• The number of core wires for the power/Input-output cable
for the main unit is 12, and the number of core wires for
the Input-output cable for the expansion units is 8.
• Power for the expansion units is supplied from the main
unit.
• When not using the I/Os of expansion units, cut the cable
near the connector.
Top is T side
Red O-ring
Left is T side
DIN rail mount type
(IB-1000/IB-1050)
Panel mount type
(IB-1500/IB-1550)
Point
Brown
Black
White
Blue
Insert further
than here.
Point
Power/Input-output cable
To attach
To remove
Point
Amplifier Functions and Displays
"Reference Light Registration (Gain
Adjustment)" (Page 7)
"Setting procedures (Basic)" (Page 8)
"Initial Reset (Initialize)" (Page 8)
"Adjust function" of the IB Series User's
Manual
"Switching the bank with button
operations" of the IB Series User's
Manual
"4-3 Calibration Function" of the IB
Series User's Manual
"3-9 Key Lock Function" of the IB Series
User's Manual
"Beam axis alignment function"
(Page 6)
Normal
The same value as the R.V. (internal measurement value) is
displayed.
When the hold function is being used
The P.V. value (judgment value) is held following the hold function
settings.
For details, refer to the IB Series User's Manual.
Brown
Blue
Black
White
Gray
Light blue
Orange
Shield
Pink
Yellow
Pink/Purple
Purple
Green
10 to 30 VDC
0 V
HIGH judgment output
LOW judgment output
GO judgment output
Analog output +
Analog output GND
External input 1 (Zero shift input)
External input 2 (Reset input)
External input 3 (Timing input)
External input 4 (Not Used)
Check output
*1
*4
*1
*1
*2
*2
*3
*3
*3
*3
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD CALC CHECK
Press [MODE] and [SET]
for 2 seconds
for 2 seconds
Press [MODE]
press [SET] for 5 times
While pressing [MODE]
press for 2 seconds
or
While pressing [MODE]
for 2 seconds
Press and
Press [MODE] and
for 2 seconds
[MODE] and , or [MODE] and
Press and
[HOLD] ON