The default settings (default values) are explained below.

When initial reset (initialization) is preformed, the following values are returned to

the default values, except for the calibration function.

"Initial Reset (Initialize)" (Page 8)

Values set on the main screen
The same values are set in banks 0 to 3.

Basic and advanced setting

z

Output circuit

When NPN output is selected

When PNP output is selected

z

Analog output circuit

z

Input circuit

When NPN output is selected

When PNP output is selected

„

Sensor amplifier

z

IB-1000/IB-1050 (Din Rail Mount Type)

z

IB-1500/IB-1550 (Panel Mount Type)

Default Settings (List of Default Values)

Setting item

Default

value

HIGH setting value

LOW setting value

Shift target value

Setting item

Default

value

Description

1. Measurement mode

2EV

Percentage mode

2. Received/Blocked light

mode

.K)J6

Received light mode

3. Averaging/High-pass filter

Average number of times 64 times

4. Output mode

PQ

Normally open

5. Hold function

5*

Sample hold

6. Timing input

.'X'.

Level

7. Delay timer

Q((

Delay timer disabled

8. Hysteresis

0.00

9. Analog output scaling

F'(.V

Scaling disabled

10. External input

F'(.V

External input function not changed from

default settings

11. Bank switching method

DVP

Button switching

12. Save zero-shift state

/Q((

Not saved in non-volatile memory

(EEPROM)

13. Save adjust state

/Q((

Not saved in non-volatile memory

(EEPROM)

14. Adjust level

2

Adjust level 20P

15. Auto adjust function

Q((

Auto adjust function disabled

16. Check output function

Q((

Check output function disabled

17. Error output mode

F'(.V

Normal mode

18. Display digit

F'(.V

Default setting

19. Power save function

Q((

OFF

20. Judgment indicator color

F'(.V

HI: Red, GO: green, LO: red

21. P.V. value display color

F'(.V

HI, LO, error: red

GO: Green

Setting item

Default

value

Description

Calibration function

F'(.V

No correction

Circuit Diagram

Main circuit

Brown

0 V

Blue

*

Load

O

vercurrent protection circuit

10 to 30 VDC

* Black (HIGH judgment output)/

White (LOW judgment output)/
Gray (GO judgment output)/
Green (check output)

10 to 30 VDC

Blue

*

Load

0 V

* Black (HIGH judgment output)/

White (LOW judgment output)/
Gray (GO judgment output)/
Green (check output)

Main circuit

Overcurrent protection circuit

Brown

Do not short-circuit the shield (analog output GND) and blue (0V).

Dimensions

(Switching number)

Shield

Orange

Analog output GND

Main circuit

Analog current output circuit

Analog voltage output circuit

Analog voltage/
current output
0 to 5 V, 1 to 5 V,
-5 to 5 V, 4 to 20 mA

NOTICE

10 to 30 VDC

*

Blue

+5V

0V

Brown

Main circuit

* Pink (External input 1)/Yellow (External input 2)/

Pink·Purple (External input 3)/
Purple (External input 4)

(Short-circuit current 2 mA or less)

10 to 30 VDC

*

Blue

0 V

* Pink (External input 1)/Yellow (External input 2)/

Pink·Purple (External input 3)/
Purple (External input 4)

(Short-circuit current 2 mA or less)

Brown

Main circuit

28.3

42.4 37.4

17.4

18.5

18.5

8.9

20

21.55

35.4

76.25

17.6

3

When the cover is open: Max. 109.2

Max. 135°

Cable diameter

φ4.7/Cable length 2 m

Cable diameter

φ4.8

44.7

15.3

4

9.5

1.5

35

20.2

2.3

7.6

73.6

48

19.1

19.1

10.3

10.3

17.6

27.2

22.4

44.7

Cable diameter

φ4.7

Cable length 2 m

Cable diameter

φ4.8