Sensor amplifier unit

z

DIN rail mount type (IB-1000/IB-1050)

z

Panel mount type (IB-1500/IB-1550)

„

Sensor head

„

DIN rail mount type, main unit (IB-1000)

Align the claw at the bottom of the main body

with the DIN rail. While pushing the main body in

the direction of the arrow (1), tilt the amplifier in

the direction of the arrow (2).

To remove the amplifier, raise the main body in

the direction of the arrow (3) while pushing it in

the direction of the arrow (1).

„

DIN rail mount type, expansion unit (IB-1050)

Expansion units must be connected to the main unit before they can be used.

Up to 3 expansion units can be connected to one main unit.

1

Remove the expansion protective cover from a IB-1000 (main unit).

2

Install the amplifiers (expansion units) onto a DIN rail.

Do the same as instructed under "DIN rail mount type, main unit."

3

Push the expansion unit into the main unit connector until a

clicking sound can be heard.

4

Install the end units (OP-26751: 2 units per set) (sold separately)

on both sides of the amplifiers (main or expansion units). Secure

the end units in place with screws on top (2 on each end unit).

The end units are mounted in the same way as the amplifiers.

Part Names

Item

Description

(1) Main display

Displays the judgment value (P.V. value) and various

setting items.

(2) Laser emission warning

indicator

Turns on while the laser beam is emitted. Flashes

when laser beam is stopped.

(3) Judgment indicator

Indicates whether the judgment value (P.V. value) in

respect to the tolerance setting is HIGH (higher than

the upper limit), GO (within tolerance range) or LOW

(lower than the lower limit).

(4) Auto adjust indicator

Turns on while the auto adjust function is operating.

(5) Bank indicator

Indicates the bank in use.

(6) Zero shift button

Press this to set the internal measurement value (R.V.

value) to the shift target value.

(7) Sub display identification

indicator

Turns on according to the type of value displayed on

the sub display.

(8) Sub display

Displays the internal measurement value (R.V. value),

analog output value and various settings (selections).

(9) Timing input indicator

If the timing input (external input) is set to level, this

indicator lights while the timing input is on. If the

timing input is set to edge, this indicator turns on for

approx. 0.5 seconds when the timing input is on.

(10) Zero shift indicator

Turns on for approx. 0.5 seconds when zero shift is

executed.

(11) SET button

When making various settings, press this button to

automatically set the setting value.

(12) MODE button

When making various settings, press this button to

start or end the setting or to move the item.

(13) Arrow buttons

Use this to select the setting item or to change the

details displayed on the sub display.

(14) Check indicator

Turns on when the check output is on.

(15) Percentage indicator

Turns on when the measurement mode is % mode.

(16) Hold indicator

Turns on when the judgment value (P.V. value) is

held.

IB

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9) (10) (11)

(16) (15) (14)

(13

(12)

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8) (9) (10) (11) (12)

(16) (15) (14)

(13)

Item

Description

(1) Laser emission

warning

indicator

Always on when the power is supplied to the sensor head. Flashes

while using the beam axis alignment function. The flashing cycle

quickens as the amount of received light increases and can be uses

as a guide for adjusting the beam axis.

"Beam axis alignment function" (Page 6)

Use a transmitter and receiver with the same serial No.

combination. The operation and accuracy cannot be

guaranteed if units with different serial numbers are used in

combination. The serial No. is attached to the top of the

transmitter and receiver.

Mounting the Amplifier

• When connecting multiple amplifiers (expansion units), first

check to make sure that the power is turned off to all of the

main and expansion units. Installing an expansion unit with

power on may damage this device.

• Push the amplifiers (expansion units) as far as possible into

the main unit. If they are connected at an angle or not inserted

securely, this device could get damaged.

• When connecting the expansion units, make sure to initialize

the expansion units and set the output polarity.

(1)When turning on the amplifier for the first time after con-

necting the sensor head please reference

"Operation When the Power Is Turned On for the First Time" (Page 6)

(2)When initializing the unit please reference

"Initial Reset (Initialize)" (Page 8)

• Expansion units with different settings for output polarity

(such as an NPN output expansion unit to a PNP output main

unit) cannot be connected together.

• Expansion units using DIN rail mount cannot be connected to

a panel mount style main unit.

Mount the amplifiers securely using the end units (OP-26751:

2 units per set) (sold separately) or a commercially available

DIN rail mounting tool to prevent the amplifiers from slipping

and coming off from the DIN rail due to machine vibration.

LASER

R

. o N

L A I

R E S

R

E

S

A

L

T

R

E

S

A

L

T

R

. o

N L

A I R

E

S

R

. o

N L

A I R

E

S

R

E

S

A

L

T

Laser Receiver

Laser transmitter

(1) Laser emission warning indicator

Receiver

Transmitter

Receiver

head

connector

Transmitter

head connector

Point

SERIAL No.

12345678

No.

12345678

Re ceive r

Transm itte r

(1)

(2)

(3)

CAUTION

Point

Connector cover

Main unit

Connecter

Expansion unit

Main unit

Point