KEYENCE DL-RS1A/IB User Manual
Page 16

14
Parameters of Commands and Responses
133
Averaging/High-pass filter
**
2
R/W
Averaging
0: 1
1: 2
2: 4
3: 8
4: 16
5: 64
6: 256
7: 1024
8: 4096
9: 16384
High-pass filter
10: 0.1Hz
11: 0.2Hz
12: 0.5Hz
13: 1Hz
14: 2Hz
15: 5Hz
16: 10Hz
17: 20Hz
18: 50Hz
19: 100Hz
5
134
Output mode
*
1
R/W
0: NO (Normally Open)
1: NC (Normally Close)
0
136
Hold function setting
*
1
R/W
0: Sample hold
1: Peak hold
2: Bottom hold
3: Peak-to-peak hold
4: Auto peak hold
5: Auto bottom hold
0
137
Auto hold trigger level
±***.** *
8
7
R/W
-999.99 to +999.99
90.00
138
Timing input
*
1
R/W
0: Level
1: Edge
0
139
Delay Timer
*
1
R/W
0: Delay timer off
1: On delay timer
2: Off delay timer
3: One shot timer
0
140
Timer duration
****
4
R/W
1 to 9999
60
141
Hysteresis
***.** *
12
6
R/W
0.00 to 999.99
0.00
142
Analog output scaling*
14
*
1
R/W
0: Do not scale (Initial state)
1: Free range
0
143
Analog output upper limit*
14
±***.** *
8
7
R/W
-999.99 to +999.99
100.00
144
Analog output lower limit*
14
±***.** *
8
7
R/W
-999.99 to +999.99
0.00
145
External input setting*
15
*
1
R/W
0: Initial state
1: User setting
0
146
External input 1 function
selection*
15
*
1
R/W
0: Zero shift input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
0
147
External input 2 function
selection*
15
*
1
R/W
0: Reset input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
0
148
External input 3 function
selection*
15
*
1
R/W
0: Timing input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
0
Data
No.
Data name
Data
format
*1
No. of
bytes
Attribute
*2
Data range
Default value
Parameters of Commands and Responses
*1
In the Data format column, "±" indicates that the value can be either "+" or "-" and "*" signifies a
number from "0 to 9".
*2
Indicates that the data can only be read from (R), can only be written to (W), or can be both read
from and written to (R/W) the sensor amplifiers.
*3
The command is executed only when the data is changed from 0 to 1. Unless the setting is
changed to 1 after the setting is changed to 0, the command is not executed.
If the sensor amplifier is turned OFF after the zero shift is performed, the previous state before
the zero shift function is used is restored. If you wish to keep the zero shift state even after the
power is turned OFF, set the Save zero-shift state function to ON.
If the sensor amplifier is turned OFF after the adjust function is performed, the previous state
before the adjust function is performed is restored. If you wish to keep the light amount
correction value even after the power is turned OFF, set the Save adjust state function to ON.
*4
Reference light amount registration error [ErG] and Adjust error [ErAdJ] are cleared.
*5
The system parameter means the polarity of judgment output and check output, and the setting
for analog output.
The execution result can be confirmed by the data number 056 (System parameter current state).
*6
When requesting execution of the Measured correction (Logical correction), the data No. "107"
must be set to Measured correction (Logical correction) before setting.
149
External input 4 function
selection*
15
*
1
R/W
0: Adjust input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
4
150
Bank switching method
*
1
R/W
0: Button
1: External input
0
152
Save zero-shift state function
*
1
R/W
0: OFF
1: ON
0
154
Display digit
*
1
R/W
0: Initial state
1: 0.0001
2: 0.001
3: 0.01
4: 0.1
5: 1
0
155
Power save function
*
1
R/W
0: OFF
1: Half
2: All
0
157
Judgment indicator color
*
1
R/W
0: GO only Green (Initial state)
1: GO only Red
2: All Green
3: All Red
0
158
P.V. value display color
*
1
R/W
0: GO Green (Initial state)
1: GO Red
2: All Green
3: All Red
0
161
Save adjust state function
*
1
R/W
0: OFF
1: ON
0
162
Adjust level
**
2
R/W
1 to 30
20
163
Auto adjust function
*
1
R/W
0: Disabled
1: Enabled
0
164
Auto adjust level
**.**
5
R/W
0.50 to 20.00
3.00
165
Check output function
*
1
R/W
0: Disabled
1: Enabled
0
166
Check output light level
**
2
R/W
1 to 30
10
167
Error output mode
*
1
R/W
0: Normal mode (Initial state)
1: LX2 compatible mode
0
168
Hysteresis for trigger level
*
1
R/W
0: Initial state
1: User setting
0
169
Hysteresis set value for trigger
level
***.** *
12
6
R/W
0.00 to 999.99
1.00
Data
No.
Data name
Data
format
*1
No. of
bytes
Attribute
*2
Data range
Default value