Data Processing Time
This section describes the length of time that lasts from detection by a sensor to data
processing by PLC.
Maximum data processing time = (1) + (2) + (3) + (4)
(1)PLC scan time
(2)RPI (Transmission cycle)
(3)DL-EP1 data communication time
(4)Sensor amplifier response time
(2)RPI is set with the scanner unit. It can be set in 0.5 ms increments between 0.5 ms
and 10000 ms.
(3)DL-EP1 data communication time
The time required for sending outputs and current value data from a sensor
amplifier to the DL-EP1 is as follows:
Sensor amplifier with calculation function OFF, or sensor amplifier with no
calculation function
* For GT2-100 series, add 50 ms to the values above.
Number of connected sensor
amplifiers
Output, judgment value, or
current value
GT2 series*
1
7.8 ms
2
9.8 ms
3
13.8 ms
4
15.8 ms
5
19.8 ms
6
21.8 ms
7
25.8 ms
8
27.8 ms
9
31.8 ms
10
33.8 ms
11
37.8 ms
12
39.8 ms
13
43.8 ms
14
45.8 ms
15
49.8 ms
CPU unit
EtherNet/IP
scanner
DL-EP1
Sensor amplifier
(1)