Group2
032AH
(810) to
033FH
(831)
Reserved for system
0340H
(832)
Group2 Entry
count
Indicates the number of items (entries) that can be
set in Group 2.
Parameter range: 20
R
DINT
0341H
(833)
Bank 0 HIGH
setting
Indicates the bank 0 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W
DINT
0342H
(834)
Bank 0 LOW
setting
Indicates the bank 0 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W
DINT
0343H
(835)
Bank 0
preset value
Indicates the bank 0 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W
DINT
0344H
(836)
Bank 0 HH
setting
*1
Indicates the bank 0 HH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 7.0000)
R/W
DINT
0345H
(837)
Bank 0 LL
setting
*1
Indicates the bank 0 LL setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W
DINT
0346H
(838)
Bank 1 HIGH
setting
Indicates the bank 1 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W
DINT
0347H
(839)
Bank 1 LOW
setting
Indicates the bank 1 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W
DINT
0348H
(840)
Bank 1
preset value
Indicates the bank 1 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W
DINT
0349H
(841)
Bank 1 HH
setting
*1
Indicates the bank 1 HH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 7.0000)
R/W
DINT
034AH
(842)
Bank 1 LL
setting
*1
Indicates the bank 1 LL setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W
DINT
034BH
(843)
Bank 2 HIGH
setting
Indicates the bank 2 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W
DINT
034CH
(844)
Bank 2 LOW
setting
Indicates the bank 2 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W
DINT
034DH
(845)
Bank 2
preset value
Indicates the bank 2 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W
DINT
Class