3 cyclic communication 3-14 – KEYENCE DL-EP1 User Manual
Page 44
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-3 Cyclic communication
3-14
3
C
om
m
uni
ca
tin
g
w
ith
the
G
T2
S
er
ies
GT2 Series
Warning code list
No warning code occurs in the DL-EP1 and in the GT2 Series sensor amplifiers
connected to the DL-EP1.
0
100
System error
The IP address is incorrect.
Contact your nearest
KEYENCE office.
101
System error
A default gateway setting
error occurred.
102
System error
An attempt to read data in
EEPROM such as the MAC
address has failed.
103
System error
An attempt to start the
protocol stack has failed.
104
System error
An attempt to access
FlashROM has failed.
150
System error
The number of held IDs is
incorrect.
151
System error
The number of sensors is
incorrect.
152
System error
An initial read error occurred.
Error
ID
Number
Code
Description
Cause
Actions
01H to
0FH
(Each
ID
number)
01H
Sensor amplifier
error 1 of each ID
number
Overcurrent error (ErC)
Refer to the GT2 Series
User's Manual.
02H
Sensor amplifier
error 2 of each ID
number
Head error (ErH)
03H
Sensor amplifier
error 3 of each ID
number
EEPROM error (ErE)
04H
Sensor amplifier
error 4 of each ID
number
Jam check error
(Er.ChK)
05H
Sensor amplifier
error 5 of each ID
number
Self-timing
delay error
(Er.dLY)
06H
Sensor amplifier
error 6 of each ID
number
Number-of-units error
(Er.Unit)
07H
Sensor amplifier
error 7 of each ID
number
Calculation error(Er.CAL)
08H
Sensor amplifier
error 8 of each ID
number
Calculation-only mode error
(Er.noH)
Error
ID
Number
Code
Description
Cause
Actions