KEYENCE DL-EP1 User Manual
Page 54
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-4 Message Communication
3-24
3
C
om
m
uni
ca
tin
g
w
ith
the
G
T2
S
er
ies
(5) Reading the number of decimal places from a sensor amplifier
Message communication reads the number of decimal places of settings read
from the sensor amplifier.
"(5) Reading the number of decimal places in the parameter from a sensor
For the GT2 Series, if the current value is 12.53 mm, data is stored as
follows:
Data: 125300
Number of decimal places: 4
Perform calculation from the read data and the number of decimal places.
If message communication writes data to a sensor amplifier, issues an
operation command to the sensor amplifier, or locks sensor amplifier
operations, the sensor amplifier button operations are locked for about 10
seconds. "COM-Lock (
)" is displayed for about 2 seconds during
switching to the locked state or when an attempt is made to operate a
locked button. When button operation is unlocked, "COM-Unlock
(
)" is displayed for about 2 seconds.
Command
Response
Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)
Reads the number of decimal
places of the GT2-7∗
comparator value (P.V. value).
Reference
12530012.530012.53mm
Number of
decimal places
4 3 2 1
Point