4 message communication 3-41 – KEYENCE DL-EP1 User Manual
Page 71
3-4 Message Communication
3-41
3
C
om
m
uni
ca
tin
g
w
ith
the
G
T2
S
er
ies
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
Group4
0384H
(900)
Response
time
Indicates the response time.
Parameter range: 0 to 5 (initial value: 3)
When the connected sensor head is GT2-H***/A***
0: HSP (3.0 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
When the connected sensor head is GT2-P***
0: HSP (12 ms)
1: 20 ms
2: 40 ms
3: 400 ms
4: 2000 ms
5: 4000 ms
R/W
DINT
0385H
(901)
Timing
type
*13
Indicates the timing type.
Parameter range: 0 to 2 (initial value: 0)
0: External timing input
1: Rising edge self-timing
2: Falling edge self-timing
R/W
DINT
0386H
(902)
Self-timing
level
Indicates the self timing level.
Parameter range: 199.9999
-199.9999 to 199.9999 (initial value: 0.5000)
R/W
DINT
0387H
(903)
Self-timing
delay type
Indicates the self-timing delay type.
Parameter range: 0 to 1 (initial value: 0)
0: Static hold
1: Delay timer
R/W
DINT
0388H
(904)
User-
specified
delay time
Indicates the user-specified delay time.
Parameter range: 0 to 9999
(initial value: 1000)
R/W
DINT
0389H
(905)
Static hold
determination
Indicates the static hold delay stable
determination.
Parameter range: 0 to 1 (initial value: 0)
0: Default
1: User
R/W
DINT
038AH
(906)
Static hold
stable range
Indicates the static hold delay stable range.
Parameter range: 0.0000 to 199.9999
(initial value: 0.0100)
R/W
DINT
038BH
(907)
Measurement
direction
Indicates the measurement increase/decrease
direction.
Parameter range: 0 to 1 (initial value: 0)
0: Normal
1: Reversed
R/W
DINT
038CH
(908)
Multiplier
Indicates the multiplier.
Parameter range: 0.1 to 100.0
(Initial value: 1.0)
R/W
DINT
038DH
(909)
Output mode
Indicates output mode.
Parameter range: 0 to 1 (initial value: 0)
0: N.O.
1: N.C.
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type