3 explicit messaging – KEYENCE DL-DN1 User Manual
Page 58
3-3 Explicit Messaging
3-32
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
*1
The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to
the SK-1000 Series Instruction Manual.
*2
Details of output status can be checked by noting the ON/OFF state of each bit.
*3
Use this parameter in combination with the comparator value property or with
the comparator value "invalid," "over," or "under."
*4
- When in sample hold:
Value "-99.998" is output.
- When not in sample hold:
The
peak
value encountered during the sampling period is output.
*5
- When in sample hold.
Value "-99.998" is output.
- When not in sample hold:
The
bottom value encountered during the sampling period is output.
*6
This is -999.8 when the temperature is not acquired correctly.
Nx10+4
7E
Display digit
R/W
0
0: Default
1: 0.001
2: 0.01
3: 0.1
4: 1
7F to
83
Reserved
Nx10+5
64
Group-5 entry count
R
4
65
Distance correction method
R/W
0
0: Initial state
1: User setting
66
Near-side distance correction
amount
R/W
25
5 to 50
67
Far-side distance correction amount
R/W
100
60 to 120
68
Area scaling
R/W
1.00 0.10 to 1.50
69 to
83
Reserved
Nx10+6
64
Group-6 entry count
R
11
65
Product code
R
Main unit: 4024
Expansion unit: 4025
66
Reserved
67
Connected sensor head
R
0: Not connected
1: The head is connected
68 to
6B
Reserved
6C
Product name 1
*16
R
Main unit: "SK-1"
Expansion unit: "SK-1"
6D
Product name 2
*16
R
Main unit: "000/"
Expansion unit: "050/"
6E
Product name 3
*16
R
Main unit: ""
Expansion unit: ""
6F
Product name 4
*16
R
Main unit: ""
Expansion unit: ""
70 to
83
Reserved
8C
Product name (16-byte reading)
*19
Main unit: "SK-1000"
Expansion unit: "SK-1050"
InstID
(DEC)
AttrID
(HEX)
Name
Description Attribute
Default
value
Parameter range