Changing a bank, 2 i/o communication – KEYENCE DL-DN1 User Manual
Page 38
3-2 I/O Communication
3-12
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
Changing a BANK
Sensor amplifier ID numbers 01 to 08 are assigned to bits 0 to 7, respectively.
For details of communication methods, see
sensor amplifiers" (page 3-18).
3-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.
Device
(DEC)
Name
Bit 7
Bit 6
...
Bit 1
Bit 0
Bit 15
Bit 14
...
Bit 9
Bit 8
n+6
External input-1 response
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
n+7
External input-2 response
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
n+8
External input-3 response
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
n+9
External input-4 response
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
n+10
Reserved
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
Device
(DEC)
Name
Bit 7
Bit 6
...
Bit 1
Bit 0
Bit 15
Bit 14
...
Bit 9
Bit 8
m+3
Request to change BANK
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
m+4
Select BANK number
Specifies a new BANK number
(2-byte unsigned integer; range: 0-3).
Device
(DEC)
Name
Bit 7
Bit 6
...
Bit 1
Bit 0
Bit 15
Bit 14
...
Bit 9
Bit 8
n+7
BANK change complete
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09
n+8
BANK change error
ID08
ID07
...
ID02
ID01
Reserved
ID15
...
ID10
ID09