- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -

1-1

DL-DN1 Overview

The DL-DN1 operates as a slave unit of DeviceNet communication. Using DeviceNet
communications, the sensor amplifiers and other units connected to the DL-DN1 can
transmit their ON/OFF control signals and current values as communication data to a
PLC or other equipment.
The DL-DN1 supports DeviceNet I/O communication (polling) and explicit messaging.
I/O polling enables data communication without the need of a ladder program. Explicit
messaging allows for reading/writing sensor amplifier parameters and issuing motion
commands to the sensor amplifiers.

System configuration example

Number of Connectable Sensor Amplifiers

The DL-DN1 can connect to multiple sensor amplifiers (a single main unit and multiple
expansion units) which support D-Bus. "D-bus" is the name of KEYENCE's wiring-
saving system for sensor amplifiers.
Different types of sensor amplifiers with D-bus support can be connected to a single
DL-DN1 unit.

How many and what types of sensor amplifiers can be connected depends on the
sensor amplifiers or units to be connected. Please inquire for details.

Overview

D-bus compatible sensor amplifier

PLC or other host device
(DeviceNet master unit)

DL-DN1 (This unit)

DeviceNet slave unit

KV

-DN20

MS

NS

ON

TERM.

Types and Number of Connectable Sensor Amplifiers

Name

Amplifier form Main unit

Expansion

unit

Maximum number of

connectable units

SK-1000
Series

DIN rail
mounting type

SK-1000

SK-1050

8
(1 main unit, 7 expansion units)