3 explicit messaging, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-DN1 User Manual
Page 57

3-3 Explicit Messaging
3-31
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
Nx10+4
64
Group-4 entry count
R
26
65
Reserved
66
Range setting
R/W
0
0: NEAR
1: FAR
2: Ib
67 to
68
Reserved
69
Averaging
R/W
5
0:
1 time
1:
2 times
2:
4 times
3:
8 times
4:
16 times
5:
64 times
6:
256 times
7: 1024 times
8: 4096 times
9: 16384 times
6A
Output mode
R/W
0
0: N.O.
1: N.C.
6B
Reserved
6C
Hold function setting
R/W
0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold
6D
Reserved
6E
Timing input setting
R/W
0
0: Level
1: Edge
6F to
70
Reserved
71
Hysteresis
R/W
0.100 0 to 99.999
72
Analog output scaling
*14
R/W
0
0: Initial state
1: Free range
73
Analog output upper limit
*14
R/W
10.000 -99.999 to 99.999
74
Analog output lower limit
*14
R/W
-10.000 -99.999 to 99.999
75
External input setting
*15
R/W
0
0: Initial state
1: User setting
76
External input 1
*15
R/W
0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Not use
77
External input 2
*15
R/W
0
0: Reset input
1: Bank A input
2: Bank B input
3: Not use
78
External input 3
*15
R/W
0
0: Timing input
1: Bank A input
2: Bank B input
3: Not use
79
External input 4
*15
R/W
4
0: Bank A input
1: Bank B input
2: Not used
7A
Bank switching method
R/W
0
0: Button
1: External input
7B
Reserved
7C
Save zero-shift state
R/W
0
0: OFF
1: ON
7D
Reserved
InstID
(DEC)
AttrID
(HEX)
Name
Description Attribute
Default
value
Parameter range