Send tare value, Scale calibration parameters, Configuration of rate-of-change – Hardy HI 2151/30WC Single-Scale Controller User Manual
Page 55

Section 7: Selectable Writes
49
Dead band Value #6
Set point #7
Set point Value #7
Preact Value #7
Dead band Value #7
Set point #8
Set point Value #8
Preact Value #8
Dead band Value #8
2
2
2
2
2
2
4
4
4
4
4
4
54
55
56
57
58
59
36
37
38
39
3A
3B
NOTE: The relays must be disabled by using Parameter #20 before performing a Force Relay with
Parameter #19.
7.7.2
SEND TARE VALUE
Send Tare Value
#
Words
#
Bytes
Parameter
#
Hex #
Send Tare Value
2
4
60
3C
7.7.3
SCALE CALIBRATION PARAMETERS
Use Block Write to do an actual calibration.
7.7.4
STICKER VALUE (THIS DATA IS NOT VALID FOR THE HI 2151/30WC)
Sticker Value
#
Words
#
Bytes
Parameter
#
Hex
#
Sticker Value
2
4
78
4E
7.7.5
CONFIGURATION OF RATE-OF-CHANGE
Configuration of Rate-of-Change
# Words
#
Bytes
Parameter
#
Hex
#
Displayed Rate-of-Change time (0 = Sec, 1 = Min, 2
= Hrs)
Rate-of-Change time base evaluation period in
seconds
Time base evaluation period:
0 = 1 second
5 = 6 seconds 10 = 60 seconds
1 = 2 sec.
6 = 10 sec.
11 = 120 sec.
2 = 3 sec.
7 = 12 sec.
12 = 240 sec.
3 = 4 sec.
8 = 15 sec.
13 = 450 sec.
4 = 5 sec.
9 =360 sec.
14 = 900 sec.
15 = 1800 sec.
1
1
2
2
80
81
50
51