HI 2151 Series Weight Controller
Profibus Interface Option
24
Block Read Data Number 29: Sticker Value
Byte Definitions
Byte Pos.
#
Words
Start Word # Bytes Start Byte
Block Read Data Number 29 (Hex 1D)
Reserved for future use
Sticker Value
Total Words/Bytes
LSB
MSB
1
2
3
0
1
1
1
4
6
0
1
2
Block Read Data Number 30: Configuration of Rate-of-Change
Byte Definitions
Byte Pos.
#
Words
Start Word # Bytes Start Byte
Block Read Number 30 (Hex 1E)
Reserved for future use
Displayed Rate-of-Change time
(0 = Sec, 1 = Min, 2 = Hrs)
Rate-of-Change time base evaluation period in seconds
Time base evaluation period:
0 = 1 second
5 = 6 seconds
10 = 60 seconds
1 = 2 seconds
6 = 10 seconds 11 = 120seconds
2 = 3 seconds
7 = 12 seconds 12 = 240seconds
3 = 4 seconds
8 = 15 seconds 13 = 450seconds
4 = 5 seconds
9 = 30 seconds 14 = 900seconds
15 = 1800 secs
Total Words/Bytes
LSB
MSB
LSB
LSB
1
1
1
3
0
1
2
1
1
2
2
6
0
1
2
4
Block Read Data Number 31: Configuration of Analog Output
Byte Definitions
Byte Pos.
#
Words
Start Word # Bytes Start Byte
Block Read Number 31 (Hex 1F)
Weight Parameter (Value)
0 = Gross
1 = Net
2 = Rate-of-Change
3 = Peak Hold
4 = Total Weight
Wt Value is a Zero Scale Analog Output
Weight Value is a Full Scale Analog Output
Total Words/Bytes
LSB
MSB
1
2
2
5
0
1
3
1
1
4
4
10
0
1
2
6