Operator selectable write example – Hardy HI 2151/30WC Single-Scale Controller User Manual
Page 53
![background image](/manuals/657640/53/background.png)
Section 7: Selectable Writes
47
Example Output from the server:
Byte
Hex#
Description
Byte 0
53
Block Write Number
Byte 1
00
Unused
Byte 2
42
Decimal Point Position (66)
Byte 3
00
Number ignored
Byte 4
03
3 Decimal Places
Byte 6
3C
Tare Value
Byte
Hex#
Description
Byte 7
00
Number ignored
Byte 8
00
Tare Value = 100 (hex)
Byte 9
00
Byte 10 01
Byte 11 00
7.6
OPERATOR SELECTABLE WRITE EXAMPLE
1. The following example is a setup to download set point #1 and #2 values (without
preacts and dead bands).
NOTE:
Any set point value can be entered into K memory.
When C1 is activated the Move Word (MOVW1) downloads the information to the weight
controller using WY17 through WY31.
K1: Contains hex 5300 (Selects Block Write #83)
K2: Contains hex 1800 (Selects parameter #24 - Set point number 1)
K3: Contains Double 790 (Sets set point 1 to 790)
K5: Contains hex 1B00 (Selects parameter #27 - Set point number 2)
K6: Contains Double 800 (Sets set point 2 to 800)
C1: Starts the program
MOVW1: Downloads the information in K1-K7 into WY17-WY23 (weight controller)