HI 2151 Series Weight Controller
Profibus Interface Option
32
Block Write Command Number 76: Send Tare Value
Byte Definitions
Byte
Pos.
#
Words
Start Word # Bytes Start Byte
Block Write Number 76 (Hex 4C)
Reserved for future use
Send Tare Value
Total Words/Bytes
LSB
MSB
1
2
3
0
1
1
1
4
6
0
1
2
Block Write Command Number 77: Scale Calibration Action
Byte Definitions
Byte
Pos.
#
Words
Start
Word
# Bytes Start Byte
Block Write Number 77 (Hex 4D)
Activate by setting and then clearing
Current weight is an empty scale
Current weight is span weight
Store critical data in the Secure Memory
Module
Restore critical data from the Secure Memory
Module
Current weight is Midpoint Linearity value
Reserved for future use
Current weight is the C2
®
reference point
Reserved for future use
Total Words/Bytes
LSB
MSB
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
1
1
0
1
1
2
0
1
Block Write Command Number 78: Scale Calibration Action
Byte Definitions
Byte Pos.
#
Words
Start Word # Bytes Start Byte
Block Write Number 78 (Hex 4E)
Reserved for future use
Calibration Parameters:
Decimal Point Position
Units of Measure (0 = Pounds 1 =
Kilograms)
C2
®
, Second Generation Calibration Load
Cell Count . (One # found on power-up)
Totalizer Decimal Position
Display Graduation Size (“count by”)
Motion Tolerance
LSB
MSB
LSB
MSB
LSB
MSB
1
1
1
1
0
1
2
3
1
1
1
1
1
1
2
0
1
2
3
4
5
6