2 monitoring a loopback request, 7 maintenance intermediate points, 1 display maintenance intermediate points – CANOGA PERKINS 9145E NID Software Version 3.1 User Manual
Page 175: Monitoring a loopback request, Maintenance intermediate points, Display maintenance intermediate points

9145E NID Software User’s Manual
Service OAM
Maintenance Intermediate Points
160
11.6.7.2 Monitoring a Loopback Request
1. To stop current Loopback processing, on the Loopback Monitoring screen (Figure 11-28 for
unicast, Figure 11-29 for sweep, or Figure 11-30 for multicast), type S and press Enter.
2. To send another Loopback Request, type R and press Enter. The Loopback Request screen
(Figure 11-32) opens.
3. To see more Multicast Loopback results, type N and press Enter.
4. Press Esc to return to the Maintenance End Point Attributes screen.
11.7 Maintenance Intermediate Points
Maintenance Intermediate Points (MIPs) are intermediate nodes within a Maintenance Domain or
Maintenance Entity Group. Up to 128 MIPs can be configured in a 9145E NID device.
11.7.1 Display Maintenance Intermediate Points
To display a list of existing MIPs, on the SOAM Configuration screen (Figure 11-7), type 6 and
press Enter. The Maintenance Intermediate Point List screen (Figure 11-33) opens.
Figure 11-33 Maintenance Intermediate Point List screen
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V03.10(GA0014) 05:15:27
---------------------MAINTENANCE INTERMEDIATE POINT LIST-----Display 1 - 3 of 3-
MIP ID LEVEL TYPE PORT MD/MEG NAME
1 0 802.1ag USER 2/
20 7 Y.1731 NETWORK 101/ag-comp-101
21 3 802.1ag NETWORK 1/Domain 1 (service)
Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
(A)dd new, (D)elete, (E)dit, ESC to return:
------------------------------------Messages-----------------------------------