B&C Technologies SA Series Industrial User Manual
Page 46

OPERATING INSTRUCTIONS
4-24
exit without modification, press RESET. The allowable values are 11 to 100 cm. Minimum Level
for Heat Function 213.
This function sets the minimum allowable water level for heat to activate. Upon entering the
function, the value will be displayed. To modify, press ENTER. Type the new value, and press
ENTER again to confirm.
Hours of Work
Function 214
Entering function 214 displays the total number of hours the machine has operated. The
display shows the value for about 3 seconds. Only complete cycles are counted for this timer –
partially complete cycles are not counted as part of the total work time.
Total Number of Washes
Function 215
This function shows the total number of wash programs executed since the machine was
installed.
Number of Washes since last Maintenance
Function 216
This function shows the total number of wash programs executed since the last required
maintenance was performed (set with function 218).
Reset Maintenance Alarm
Function 217
This function resets the maintenance alarm, but does not clear the number of washes counter
(function 215).
Maintenance Required
Function 218
This function sets the number of washes before the maintenance alarm is activated. The
default value is 450. This means that after 450 wash programs have been completed, the
maintenance alarm will be displayed. To change the value, use the INC or DEC keys. The value
changes by 10 each time a key is pressed. You may hold down the key to change the number
quickly. Once the desired value is reached, press the ENTER key to confirm.
Spin Safety Coast Down Time
Function 219
Upon entering function 219, you display the spin safety coast down time. If you wish to
change this (not recommended), press ENTER, followed by the new value, then ENTER to
confirm. To exit without changing the value, press RESET