B&C Technologies SA Series Industrial User Manual
Page 43

OPERATING INSTRUCTIONS
4-21
Indicates the programmed temperature was not reached within the allotted time. The most common
cause is a malfunctioning auxiliary heating system. A short WDT time and very cold water can also
cause this problem. Pressing the START key will cancel the alarm.
Indicates the programmed level was not reached within the allotted time. The most common causes:
During Fill
¾ Faulty water inlet
¾ Low or no water pressure
¾ Faulty drain valve
¾ Problem with water level tube Pressing START will continue the program, while RESET will
cancel the program.
During Fill
¾ Drain valve blocked
¾ Drain hose blocked
¾ Faulty Drain valve
Press RESET to end the program.
Indicates a fault in the drive system. On inverter driven equipment, indicates a drive fault, on non
inverter driven equipment, indicates a motor overload condition. Press RESET to clear the fault. If
this fault recurs during the next wash program, contact a qualified service technician.
Indicates the door is not closed properly. This fault disables the machine until cleared, and aborts a
program if active. Press RESET to clear the fault.
Indicates a water level of greater than 2 cm. an onset of spin. The machine will resume the spin
when the level falls below the threshold. Press RESET to abort the cycle.
Access Functions
All machine functions are accessed by pressing START and RESET simultaneously. At the
changed prompt, enter the required function.
12
Cycle (segment) Programming
27 Wash
Programming
45
Motor rotation programming (agitation profiles).
181
Clears all programs. Will delete anything programmed in memory.
201
Language: 1 – Italian, 2 – English, 3 – German, 4 – Spanish, 5 – French.
WDT LEVEL EXPIRED
OVERLOADED!
DOOR OPEN!
DRAIN