B&C Technologies SA Series Industrial User Manual
Page 44

OPERATING INSTRUCTIONS
4-22
205
16 or 24 relay output.
207 Maximum
RPM.
209
Temperature hysterisis (1 – 10 degrees C). 3 degrees C is default.
210
Temperature displayed in degrees C.
211
Temperature displayed in degrees F.
212
Maximum water level (10 -100cm).
213
Minimum water level for heating (230cm).
214
Display number of hours in operation.
215
Display total number of programs run.
216
Display number of wash programs run since last maintenance request.
217
Reset maintenance request.
218
Display and set the number of washes between maintenance requests.
219
Coast down safety timer. DO NOT MODIFY!
220
Deletes all programs and cycles from memory.
221
Copy from control to the memory card.
222
Copy from memory card to the control (programs and cycles only).
223
Copy from memory card to the control (programs, cycles and parameters).
225
Disables the ADVANCE key.
230
Maximum water level allowed during spin DO NOT MODIFY!
Maintenance Request
It is possible to set a number of wash programs to execute, following which the machine will call
for maintenance:
The message appears at the start of a program, and is repeated at the beginning of each wash
program until reset by a qualified service technician.
Disable the Machine
Function 118
Upon entering this function, the machine will not operate. The power must be cycled
(turned off, then back on) for the function to activate. Upon power up, the display will show:
To re – enable the machine, type 118 at prompt. START + RESET are not needed.
MAINT. REQ.
!