SPECIFICATION/COMPONENT IDENTIFICATION

2-3

Units

MODEL

Metric

US

SA 475 Tilt

DOOR OPENING AND HEIHGT:

Diameter mm

in

1016

40

Height of door bottom above floor

mm

in

1611

63.43

DRIVE INFORMATION:

Number of motors

Number

1

1

Size of motor

kW

Hp

30

40

WATER INLETS:

Hot water size

DN

in

50.8

2

Cold water size

DN

in

50.8

2

Additional water Inlet

DN

in

-

-

Average HOT water consumption / cycle

liters

gal

-

-

Average COLD water consumption / cycle

liters

gal

-

-

DRAIN OUTLETS AND CAPACITY:

Number of drains standard

Number

2

Number of drains optional (water re – use)

Number

2

Drain size

mm

in

203.2

8

Drain capacity

liter / cycle

g.p.m.

1050

277

STEAM INLET AND CONSUMPTION:

Steam inlet size

DN

in

38.1

1-1/2

Required steam to heat bath 10 ºF (5.55 ºC) LOW

kg

lbs

-

-

Required steam to heat bath 10 ºF (5.55 ºC) HIGH

kg

lbs

-

-

Average steam consumption

kg / hr

lbs / hr

94

207

AIR INLET AND CONSUMPTION:

Air inlet size

DN

in

12.7

1/2

Average air consumption per cycle

m

3

cfm 0.01 0.1