Welch Allyn Corival V2 - User Manual User Manual
Page 20

Operator Manual
Corival
 
 
20
 
 
 
 
 
 
 
With the ▲ ♥ keys you can select the desired protocol (in this example name1) to edit. Select 
NEW to program a new exercise protocol and give the protocol a useful name maximal 10 
characters with the▲ ♥ keys. The allowed characters for the name are: ’0∆..∆9∆,∆a∆..∆z∆, 
and ∆ ∆. Move the cursor with the confirmation button ( ) OK to the 10
th
position and the
program screen will appear: 
 
 
On top the protocol name is mentioned. The second line will give you information about the 
status of the programmed momentary workload (P) and time (t). The third line is the actual 
program line. The stage number with the type of stage is mentioned, followed by the 
programmable parameters (workload in the above example) and time. Those parameters are 
displayed as ♪ Power (dP) and ♪ time (dt). ♪ P is the change in power expressed in watts. ♪ t 
is the change in time expressed in seconds. The underlined character is the item which can be 
changed, in the example mentioned above: S. Pressing the ▲ ♥ keys give you the ability to 
toggle between the possibilities for programming a stage in a protocol: S, T, L, H, P and 
Recovery. 
 
S= step 
the workload can be adjusted + or º and the duration of this hyperbolic 
stage can be determined; the load is independent of the RPM 
T= torque
fixed torque: the torque in Nm can be adjusted with certain duration
L= linear
the workload is coupled with RPM with constant π as the adjustable 
parameter for the desired duration; load P = π * N
2
[W] goes up with
square of cadence.
H= heart rate
the workload is regulated as a function of the adjustable heart rate for a 
certain duration in this heart rate controlled step. 
P= proportional the workload is increased linear as a function of time (ramp protocol). It
will take the total duration time to reach the programmed workload;
R = Repeat
repeat steps (until max. workload): you have to enter the workload step and 
the duration of the step only once. 
Recovery
the recovery stage is the last stage of a protocol with a fixed workload and 
an unlimited duration (only 1 recovery stage in 1 protocol) 
After the confirmation of the workload during the recovery stage the menu PROGRAM BPM 
will appear. Toggle with the ▲ ♥ keys for the measurement possibilities: 
 
No BPM 
no BPM module available, select this option when the BPM is not installed, or 
no automatic blood pressure measurement during this protocol; 
Repeat
allows you to program a repeat time in minutes during the exercise stages:
New 
 name1 
name2 
esc ok 
Name 1 
Step P= 0W t=00:00 
1S dP=+050W dt=060s 
Esc ok 