beautypg.com

Press enter, Press enter. the model 400 responds: “enter, Enter – Vintage Cellars FGD-0400 User Manual

Page 78

background image

5. Press ENTER.

ENTER

PM

The Model 400 responds: “Enter high temperature limit.”

6. Using the number keys, enter the value for high temperature
limit. The Model 400 recites the digits as they are pressed.

4

MAX CALLS

5

TEMP LIMITS

6

CALIBRATE

8

CLOCK

3

INTERCALL

TIME

7

RECOGNITION

TIME

9

LISTEN TIME

SOUND

0

ID NUMBER

POWER

1

CALL

DELAY

2

VOICE

REPS

7. Press ENTER. The Model 400 responds: “Enter.”

ENTER

PM

NOTE

Do not set temperature limits too close to normal
room temperature. Minor temperature fluctuations
could result in frequent and unnecessary alarm
dialouts.

5.4.2 Disabling Alarm Response to High or Low

Temperature

To disable alarm response to either high or low temperature
settings exclusively, enter the following temperature limit when
programming the selected zone. (The Model 400 will not respond
to temperatures encountered at maximum settings or beyond.)
Begin by following the key sequence shown in Section 5.4.1, and
when prompted to enter the high or low temperature value:

• Set high temperature to either +150º F or +65º C (high

temperature limit) to prevent the Model 400 from
responding to a high temperature alarm.

• Set low temperature to either -20° F or -30° C to prevent the

Model 400 from responding to a low temperature alarm.