Problem

Cause

Solution

1.

Can’t

program

temperature

limits;

or

the

unit

won’t

read

the

temperature

sensor.

2.

The

temperature

reading

is

-20°

F

or

-30°

C.

3.

Temperature

reads

150°

F

or

65°

C.

4.

Temperature

reading

is

inaccurate.

The

zone

isn’t

configured

to

read

a

tempera

-

ture

sensor.

The

temperature

sensor

has

been

disconnected

or

has

broken

wires.

Temperature

sensor

wires

are

touching

or

have

shorted.

a)

Temperature

sensing

may

be

affected

by

a

source

of

ambient

heat

(ie.,

direct

sunlight,

or

heat

duct

proximity).

b)

Temperature

may

require

calibration.

c)

The

unit

is

using

the

wrong

temperature

scale

(Fahrenheit

vs.

Celsius).

Press

SET

and

CONFIGURE

to

program

the

zone.

(See

Section

5.1.1

for

more

information

on

configuring

zones.)

Examine

the

wires

to

temperature

sensor

and

connect

or

replace

wiring.

Verify

and

correct

wiring.

Try

moving

the

unit

to

a

different

location.

After

moving

or

placing

the

unit

away

from

ambient

heat

sources,

the

temperature

may

be

calibrated

to

offset

inaccurate

normal

reading

by

several

degrees.

Refer

to

Chapter

5,

Section

5.6.

Verify

temperature

scale.

Refer

to

Chapter

5,

Section

5.5.

Temperature